Franklin Resimatic ART Automatic Pump Controller
Franklin Resimatic ART Automatic Pump Controller
Couldn't load pickup availability
✓ Australian family-owned business
✓ Based in Inverell, NSW
✓ All prices include GST
✓ Secure online checkout
✓ Australia-wide delivery
✓ Need sizing help? Call 0408 055 236
The Pump Shed Australia
The Franklin Resimatic ART Automatic Pump Controller provides automatic start-and-stop control and dry-running protection for compatible 230V single-phase water pumps up to 1.5kW and 10 amps.
The Resimatic monitors both system pressure and water flow. Opening a tap causes the controller to start the pump automatically. When demand finishes and flow stops, the controller shuts the pump down after approximately 10 seconds.
Starting pressure is adjustable between 1.5 and 3 bar, allowing the controller to be matched to the requirements of the pump and water system. An integrated pressure gauge allows the system pressure to be checked during installation and operation.
The ART Automatic Reset Test function periodically attempts to restart the pump after a dry-running shutdown. This allows the system to resume operating automatically when the water supply returns, without requiring an immediate manual reset.
Key features
- Automatic pump starting and stopping
- Adjustable starting pressure from 1.5 to 3 bar
- Integrated pressure and flow sensors
- Dry-running protection
- Automatic restart attempts after a dry-running shutdown
- Integrated pressure gauge
- Integrated small accumulation system
- Helps prevent frequent cycling from dripping taps or minor leaks
- Protection against water hammer
- Manual restart button
- Power, pump-running and fault indicator lights
- IP65 enclosure
- Maximum working pressure of 10 bar
- Maximum water temperature of 50°C
- Maximum pump motor rating of 1.5kW
- Maximum rated current of 10 amps
Compatible pumps and applications
Suitable for correctly selected:
- Franklin MH 230V single-phase horizontal multistage pumps
- Other compatible 230V single-phase surface pumps
- Compatible single-phase submersible pump systems
- Domestic household pressure systems
- Rainwater supply systems
- Rural water systems
- Garden irrigation
- Water transfer and pressure boosting
The factory lead-fitted versions are specifically supplied with plug-and-play leads for compatible Franklin MH pump builds.
Compatibility with Franklin EVR pumps or other pump ranges must be confirmed against the motor current, motor power, electrical connection and required system pressure before ordering.
What is included
All variants include:
- Genuine Franklin Resimatic ART controller
- Integrated pressure and flow sensing
- Integrated pressure gauge
- Integrated small accumulation system
- Automatic Reset Test dry-running protection
- Manual restart button and indicator lights
The lead-fitted variants also include:
- Factory-fitted cable
- Plug-and-play electrical leads for compatible Franklin MH pump builds
What is not included
- Water pump
- Pipe unions, reducers or plumbing fittings
- Isolation valves
- Separate electrical circuit protection
- Large external pressure tank
- Water-level probes
- Installation labour
- Plug-and-play leads with the standard non-lead variants
- Replacement electronic board
Installation and selection warning
The Franklin Resimatic ART is not a variable-speed controller and does not regulate the motor speed or maintain a selected outlet pressure. It automatically starts and stops the pump using pressure and flow sensing.
The pump must be 230V single phase, no larger than 1.5kW and have a full-load current no higher than 10 amps. Both the motor power and current limits must be checked before installation.
The adjustable starting pressure must be set below the pressure the pump can reliably produce after allowing for suction lift, pumping water level, elevation and pipe-friction losses. An incorrectly selected starting pressure can prevent the pump from starting correctly or cause unreliable operation.
Maximum working pressure is 10 bar and maximum water temperature is 50°C. The IP65 enclosure is not designed for immersion or flooding. Install the controller in the correct flow direction and provide suitable isolation and service access.
Electrical installation of the standard non-lead versions must be completed by a licensed electrician. The dry-running protection does not replace direct tank or bore water-level protection where positive level control is required.
Technical information is confirmed by Franklin Electric’s Resimatic ART product information.