{"product_id":"franklin-cp3-three-phase-pump-control-panel-415v-dol-starter","title":"Franklin CP3 Three-Phase Pump Control Panel – 415V DOL Starter","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Franklin CP3 Three-Phase Pump Control Panel provides direct-on-line starting and thermal-overload protection for compatible 415V three-phase water pumps.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eEach panel is housed in an IP56 polycarbonate enclosure and includes a Manual\/Off\/Automatic selector on the front. A control terminal allows connection of either a compatible pressure switch or float switch for automatic pump operation.\u003c\/p\u003e\n\u003cp\u003eTen panel sizes are available for motors from 0.37kW through to 7.5kW. The correct panel must be selected using both the pump’s motor rating and full-load current.\u003c\/p\u003e\n\u003ch4\u003eKey features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e415V three-phase direct-on-line pump starter\u003c\/li\u003e\n\u003cli\u003eAdjustable thermal-overload protection\u003c\/li\u003e\n\u003cli\u003eIP56 polycarbonate enclosure\u003c\/li\u003e\n\u003cli\u003eManual\/Off\/Automatic selector\u003c\/li\u003e\n\u003cli\u003eConnection for one pressure switch or float switch\u003c\/li\u003e\n\u003cli\u003eAvailable from 0.37kW to 7.5kW\u003c\/li\u003e\n\u003cli\u003eOptional protection equipment can be factory fitted\u003c\/li\u003e\n\u003cli\u003eFranklin Electric two-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSuitable applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin EVR 415V three-phase vertical multistage pumps\u003c\/li\u003e\n\u003cli\u003eFranklin MH 415V three-phase horizontal multistage pumps\u003c\/li\u003e\n\u003cli\u003eFranklin FPS 415V three-phase bore pumps\u003c\/li\u003e\n\u003cli\u003eCompatible three-phase transfer and irrigation pumps\u003c\/li\u003e\n\u003cli\u003eTank filling or emptying using a compatible float switch\u003c\/li\u003e\n\u003cli\u003ePressure systems using a compatible pressure switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat is included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin CP3 assembled control panel\u003c\/li\u003e\n\u003cli\u003eDirect-on-line three-phase starter\u003c\/li\u003e\n\u003cli\u003eThermal-overload unit matching the selected variant\u003c\/li\u003e\n\u003cli\u003eIP56 polycarbonate enclosure\u003c\/li\u003e\n\u003cli\u003eManual\/Off\/Automatic selector\u003c\/li\u003e\n\u003cli\u003eControl terminal for either a pressure switch or float switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNot included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePump or motor\u003c\/li\u003e\n\u003cli\u003ePressure switch\u003c\/li\u003e\n\u003cli\u003eFloat switch\u003c\/li\u003e\n\u003cli\u003eWater-level probes\u003c\/li\u003e\n\u003cli\u003eBLC probe relay\u003c\/li\u003e\n\u003cli\u003eNo-flow or dry-run protection\u003c\/li\u003e\n\u003cli\u003ePhase-failure protection\u003c\/li\u003e\n\u003cli\u003ePressure gauge or pressure tank\u003c\/li\u003e\n\u003cli\u003eElectrical cable or installation\u003c\/li\u003e\n\u003cli\u003eFactory-fitted CP3 options unless specifically ordered\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003eInstallation and selection warning\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cblockquote\u003e\n\u003cp\u003eThree-phase electrical installation must be completed by a licensed electrician. Select the panel using the motor’s full-load nameplate current as well as its kW rating. The overload must be correctly adjusted during commissioning.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003eThe standard CP3 does not provide dry-run, probe, no-flow, phase-failure, high-pressure or low-pressure protection unless the correct optional equipment is factory fitted.\u003c\/p\u003e\n\u003cp\u003eIt is not a variable-speed controller and is not suitable for 230\/240V single-phase or solar pumps.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"0.37kW – 1.1 to 1.6 Amp Thermal Overload – 415V Three Phase","offer_id":43619618357296,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"0.55kW – 1.4 to 2.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619618390064,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"0.75kW – 1.8 to 2.5 Amp Thermal Overload – 415V Three Phase","offer_id":43619618422832,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"1.1kW – 2.3 to 3.1 Amp Thermal Overload – 415V Three Phase","offer_id":43619618455600,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"1.5kW – 2.9 to 4.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619618488368,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"2.2kW – 4.5 to 6.3 Amp Thermal Overload – 415V Three Phase","offer_id":43619618521136,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"3.0kW – 5.5 to 7.5 Amp Thermal Overload – 415V Three Phase","offer_id":43619618553904,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"4.0kW – 7.2 to 10.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619618586672,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"5.5kW – 11.3 to 16.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619618619440,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"7.5kW – 15.0 to 20.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619618652208,"sku":null,"price":939.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/22223bb8-967f-4b53-9c55-53ee01c9202b_71a2f5bf-3392-4c4a-90d8-8b4c0dac4b7c.png?v=1789455587","url":"https:\/\/thepumpshedaustralia.com.au\/products\/franklin-cp3-three-phase-pump-control-panel-415v-dol-starter","provider":"The Pump Shed Australia","version":"1.0","type":"link"}