{"title":"Franklin Pump Accessories, Controls \u0026 Protection","description":"\u003ch2\u003e\u003cspan\u003eFranklin Pump Accessories, Controls \u0026amp; Protection\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComplete your Franklin Electric pumping system with compatible controls, protection equipment and installation accessories.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur range includes motor control panels, pump protection devices, water-level probes, float and flow switches, submersible electrical cable, bore caps, check valves, pressure tanks, stainless-steel safety cable and pump shrouds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAccessories must be correctly matched to the pump voltage, motor size, cable distance and application. Contact The Pump Shed Australia if you need help selecting compatible equipment for your Franklin pump.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"franklin-cp1-single-phase-pump-control-panel","title":"Franklin CP1 Single-Phase Pump Control Panel","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Franklin CP1 Single-Phase Pump Control Panel provides direct-on-line starting and thermal-overload protection for compatible 230V single-phase water pumps.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eEach panel is supplied in an IP56 polycarbonate enclosure with a Manual\/Off\/Automatic selector on the front. A control terminal allows connection of either a compatible pressure switch or float switch for automatic pump operation.\u003c\/p\u003e\n\u003cp\u003eSeven panel sizes are available from 0.37kW to 3.7kW. The correct panel must be selected using both the pump’s motor rating and full-load current.\u003c\/p\u003e\n\u003ch4\u003eKey features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e230V single-phase direct-on-line pump starter\u003c\/li\u003e\n\u003cli\u003eAdjustable thermal-overload protection\u003c\/li\u003e\n\u003cli\u003eIP56 polycarbonate enclosure\u003c\/li\u003e\n\u003cli\u003eManual\/Off\/Automatic selector\u003c\/li\u003e\n\u003cli\u003eConnection for one pressure switch or float switch\u003c\/li\u003e\n\u003cli\u003eAvailable for motors from 0.37kW to 3.7kW\u003c\/li\u003e\n\u003cli\u003eFranklin Electric two-year warranty\u003c\/li\u003e\n\u003cli\u003eOptional protection equipment can be factory fitted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSuitable applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin MH 230\/240V single-phase multistage pumps\u003c\/li\u003e\n\u003cli\u003eFranklin EVR 230\/240V single-phase vertical multistage pumps\u003c\/li\u003e\n\u003cli\u003eCompatible single-phase transfer and irrigation pumps\u003c\/li\u003e\n\u003cli\u003eCompatible two-wire submersible pumps where the motor current falls within the selected overload range\u003c\/li\u003e\n\u003cli\u003eTank filling or emptying when connected to a suitable float switch\u003c\/li\u003e\n\u003cli\u003eAutomatic pressure systems when connected to a suitable pressure switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat is included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin CP1 assembled control panel\u003c\/li\u003e\n\u003cli\u003eDirect-on-line motor starter\u003c\/li\u003e\n\u003cli\u003eThermal-overload unit matching the selected variant\u003c\/li\u003e\n\u003cli\u003eIP56 polycarbonate enclosure\u003c\/li\u003e\n\u003cli\u003eManual\/Off\/Automatic selector\u003c\/li\u003e\n\u003cli\u003eTerminal for either a pressure switch or float switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNot included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePressure switch\u003c\/li\u003e\n\u003cli\u003eFloat switch\u003c\/li\u003e\n\u003cli\u003eWater-level probes\u003c\/li\u003e\n\u003cli\u003eBLC probe relay\u003c\/li\u003e\n\u003cli\u003eDry-run or no-flow protection\u003c\/li\u003e\n\u003cli\u003ePressure gauge or pressure tank\u003c\/li\u003e\n\u003cli\u003ePump, wiring, cable or installation\u003c\/li\u003e\n\u003cli\u003eThree-wire submersible motor control box\u003c\/li\u003e\n\u003cli\u003eFactory-fitted CP1 protection options unless specifically ordered\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eI could not find a reliable Australian retailer listing these exact CP1 order numbers. Pumptec, Pumptec Plus and ordinary Franklin submersible motor control boxes are different products and should not be used as price comparisons.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eInstallation and selection warning\u003c\/h3\u003e\n\u003cblockquote\u003e\n\u003cp class=\"\"\u003eElectrical installation must be completed by a licensed electrician. Select the panel using the motor nameplate current as well as motor kW. The thermal overload must be correctly adjusted during commissioning. The CP1 is not a variable-speed controller and standard panels do not provide dry-run, probe, no-flow, high-pressure or low-pressure protection. Optional CP1 protection equipment must be specified and factory fitted when the panel is ordered.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"The Pump Shed Australia","offers":[{"title":"0.37kW – 4 to 6 Amp Thermal Overload – 230V Single Phase","offer_id":43619590111280,"sku":null,"price":869.0,"currency_code":"AUD","in_stock":true},{"title":"0.55kW – 5.5 to 8 Amp Thermal Overload – 230V Single Phase","offer_id":43619590144048,"sku":null,"price":869.0,"currency_code":"AUD","in_stock":true},{"title":"0.75kW – 5.5 to 8 Amp Thermal Overload – 230V Single Phase","offer_id":43619590176816,"sku":null,"price":869.0,"currency_code":"AUD","in_stock":true},{"title":"1.1kW – 7 to 10 Amp Thermal Overload – 230V Single Phase","offer_id":43619590209584,"sku":null,"price":869.0,"currency_code":"AUD","in_stock":true},{"title":"1.5kW – 9 to 13 Amp Thermal Overload – 230V Single Phase","offer_id":43619590242352,"sku":null,"price":869.0,"currency_code":"AUD","in_stock":true},{"title":"2.2kW – 12 to 18 Amp Thermal Overload – 230V Single Phase","offer_id":43619590275120,"sku":null,"price":869.0,"currency_code":"AUD","in_stock":true},{"title":"3.7kW – 16 to 24 Amp Thermal Overload – 230V Single Phase","offer_id":43619590307888,"sku":null,"price":1059.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/22223bb8-967f-4b53-9c55-53ee01c9202b.png?v=1789455246"},{"product_id":"franklin-cp3-three-phase-pump-control-panel-415v-dol-starter","title":"Franklin CP3 Three-Phase Pump Control Panel – 415V DOL Starter","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Franklin CP3 Three-Phase Pump Control Panel provides direct-on-line starting and thermal-overload protection for compatible 415V three-phase water pumps.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eEach panel is housed in an IP56 polycarbonate enclosure and includes a Manual\/Off\/Automatic selector on the front. A control terminal allows connection of either a compatible pressure switch or float switch for automatic pump operation.\u003c\/p\u003e\n\u003cp\u003eTen panel sizes are available for motors from 0.37kW through to 7.5kW. The correct panel must be selected using both the pump’s motor rating and full-load current.\u003c\/p\u003e\n\u003ch4\u003eKey features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e415V three-phase direct-on-line pump starter\u003c\/li\u003e\n\u003cli\u003eAdjustable thermal-overload protection\u003c\/li\u003e\n\u003cli\u003eIP56 polycarbonate enclosure\u003c\/li\u003e\n\u003cli\u003eManual\/Off\/Automatic selector\u003c\/li\u003e\n\u003cli\u003eConnection for one pressure switch or float switch\u003c\/li\u003e\n\u003cli\u003eAvailable from 0.37kW to 7.5kW\u003c\/li\u003e\n\u003cli\u003eOptional protection equipment can be factory fitted\u003c\/li\u003e\n\u003cli\u003eFranklin Electric two-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSuitable applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin EVR 415V three-phase vertical multistage pumps\u003c\/li\u003e\n\u003cli\u003eFranklin MH 415V three-phase horizontal multistage pumps\u003c\/li\u003e\n\u003cli\u003eFranklin FPS 415V three-phase bore pumps\u003c\/li\u003e\n\u003cli\u003eCompatible three-phase transfer and irrigation pumps\u003c\/li\u003e\n\u003cli\u003eTank filling or emptying using a compatible float switch\u003c\/li\u003e\n\u003cli\u003ePressure systems using a compatible pressure switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat is included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin CP3 assembled control panel\u003c\/li\u003e\n\u003cli\u003eDirect-on-line three-phase starter\u003c\/li\u003e\n\u003cli\u003eThermal-overload unit matching the selected variant\u003c\/li\u003e\n\u003cli\u003eIP56 polycarbonate enclosure\u003c\/li\u003e\n\u003cli\u003eManual\/Off\/Automatic selector\u003c\/li\u003e\n\u003cli\u003eControl terminal for either a pressure switch or float switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNot included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePump or motor\u003c\/li\u003e\n\u003cli\u003ePressure switch\u003c\/li\u003e\n\u003cli\u003eFloat switch\u003c\/li\u003e\n\u003cli\u003eWater-level probes\u003c\/li\u003e\n\u003cli\u003eBLC probe relay\u003c\/li\u003e\n\u003cli\u003eNo-flow or dry-run protection\u003c\/li\u003e\n\u003cli\u003ePhase-failure protection\u003c\/li\u003e\n\u003cli\u003ePressure gauge or pressure tank\u003c\/li\u003e\n\u003cli\u003eElectrical cable or installation\u003c\/li\u003e\n\u003cli\u003eFactory-fitted CP3 options unless specifically ordered\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003eInstallation and selection warning\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cblockquote\u003e\n\u003cp\u003eThree-phase electrical installation must be completed by a licensed electrician. Select the panel using the motor’s full-load nameplate current as well as its kW rating. The overload must be correctly adjusted during commissioning.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003eThe standard CP3 does not provide dry-run, probe, no-flow, phase-failure, high-pressure or low-pressure protection unless the correct optional equipment is factory fitted.\u003c\/p\u003e\n\u003cp\u003eIt is not a variable-speed controller and is not suitable for 230\/240V single-phase or solar pumps.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"0.37kW – 1.1 to 1.6 Amp Thermal Overload – 415V Three Phase","offer_id":43619618357296,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"0.55kW – 1.4 to 2.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619618390064,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"0.75kW – 1.8 to 2.5 Amp Thermal Overload – 415V Three Phase","offer_id":43619618422832,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"1.1kW – 2.3 to 3.1 Amp Thermal Overload – 415V Three Phase","offer_id":43619618455600,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"1.5kW – 2.9 to 4.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619618488368,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"2.2kW – 4.5 to 6.3 Amp Thermal Overload – 415V Three Phase","offer_id":43619618521136,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"3.0kW – 5.5 to 7.5 Amp Thermal Overload – 415V Three Phase","offer_id":43619618553904,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"4.0kW – 7.2 to 10.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619618586672,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"5.5kW – 11.3 to 16.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619618619440,"sku":null,"price":899.0,"currency_code":"AUD","in_stock":true},{"title":"7.5kW – 15.0 to 20.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619618652208,"sku":null,"price":939.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/22223bb8-967f-4b53-9c55-53ee01c9202b_71a2f5bf-3392-4c4a-90d8-8b4c0dac4b7c.png?v=1789455587"},{"product_id":"franklin-cp3-eco-basic-three-phase-pump-starter-415v-dol","title":"Franklin CP3 Eco Basic Three-Phase Pump Starter – 415V DOL","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Franklin CP3 Eco Basic Three-Phase Pump Starter provides straightforward manual starting, stopping and thermal-overload protection for compatible 415V three-phase water pumps.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIt is a compact direct-on-line starter with green start and red stop push buttons. Ten models are available for motors from 0.37kW through to 7.5kW.\u003c\/p\u003e\n\u003cp\u003eThe correct starter must be selected using the pump motor’s full-load nameplate current as well as its kW rating.\u003c\/p\u003e\n\u003ch4\u003eKey features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e415V three-phase direct-on-line starter\u003c\/li\u003e\n\u003cli\u003eManual start and stop push buttons\u003c\/li\u003e\n\u003cli\u003eThermal-overload protection\u003c\/li\u003e\n\u003cli\u003eCompact enclosed design\u003c\/li\u003e\n\u003cli\u003eAvailable from 0.37kW to 7.5kW\u003c\/li\u003e\n\u003cli\u003eSuitable for straightforward manually operated pump installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSuitable applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin MH 415V three-phase multistage pumps\u003c\/li\u003e\n\u003cli\u003eFranklin EVR 415V three-phase vertical multistage pumps\u003c\/li\u003e\n\u003cli\u003eFranklin FPS 415V three-phase bore pumps where additional protection is installed separately\u003c\/li\u003e\n\u003cli\u003eManual water-transfer systems\u003c\/li\u003e\n\u003cli\u003eIrrigation and wash-down pumps\u003c\/li\u003e\n\u003cli\u003eCompatible 415V three-phase clean-water pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat is included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin CP3 Eco Basic enclosed starter\u003c\/li\u003e\n\u003cli\u003eDirect-on-line contactor\u003c\/li\u003e\n\u003cli\u003eThermal-overload unit matching the selected variant\u003c\/li\u003e\n\u003cli\u003eGreen manual start button\u003c\/li\u003e\n\u003cli\u003eRed manual stop button\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNot included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePump or motor\u003c\/li\u003e\n\u003cli\u003eManual\/Off\/Automatic selector\u003c\/li\u003e\n\u003cli\u003ePressure-switch or float-switch automatic-control input\u003c\/li\u003e\n\u003cli\u003eDry-run or no-flow protection\u003c\/li\u003e\n\u003cli\u003eWater-level probe relay or probes\u003c\/li\u003e\n\u003cli\u003ePhase-failure protection\u003c\/li\u003e\n\u003cli\u003eHigh-pressure or low-pressure protection\u003c\/li\u003e\n\u003cli\u003eTimer or remote control\u003c\/li\u003e\n\u003cli\u003eElectrical cable or installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eInstallation must be completed by a licensed electrician. Select the starter using the motor’s full-load nameplate current—not motor kW alone. The overload must be correctly adjusted during commissioning.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003eThe CP3 Eco Basic is intended for straightforward manual start\/stop operation. It does not replace the full CP3 panel where automatic pressure, tank-level, probe, no-flow or dry-run protection is required.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"0.37kW – 1.1 to 1.6 Amp Thermal Overload – 415V Three Phase","offer_id":43619657580592,"sku":null,"price":270.0,"currency_code":"AUD","in_stock":true},{"title":"0.55kW – 1.4 to 2.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619657613360,"sku":null,"price":270.0,"currency_code":"AUD","in_stock":true},{"title":"0.75kW – 1.8 to 2.5 Amp Thermal Overload – 415V Three Phase","offer_id":43619657646128,"sku":null,"price":270.0,"currency_code":"AUD","in_stock":true},{"title":"1.1kW – 2.3 to 3.1 Amp Thermal Overload – 415V Three Phase","offer_id":43619657678896,"sku":null,"price":270.0,"currency_code":"AUD","in_stock":true},{"title":"1.5kW – 2.9 to 4.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619657711664,"sku":null,"price":270.0,"currency_code":"AUD","in_stock":true},{"title":"2.2kW – 4.5 to 6.3 Amp Thermal Overload – 415V Three Phase","offer_id":43619657744432,"sku":null,"price":270.0,"currency_code":"AUD","in_stock":true},{"title":"3.0kW – 5.5 to 7.5 Amp Thermal Overload – 415V Three Phase","offer_id":43619657777200,"sku":null,"price":270.0,"currency_code":"AUD","in_stock":true},{"title":"4.0kW – 7.2 to 10.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619657809968,"sku":null,"price":270.0,"currency_code":"AUD","in_stock":true},{"title":"5.5kW – 11.3 to 16.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619657842736,"sku":null,"price":270.0,"currency_code":"AUD","in_stock":true},{"title":"7.5kW – 15.0 to 20.0 Amp Thermal Overload – 415V Three Phase","offer_id":43619657875504,"sku":null,"price":270.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Franklin-CP3-Eco-Basic-Three-Phase-Starter.jpg?v=1789458106"},{"product_id":"franklin-pumptec-single-phase-bore-pump-protection-230v","title":"Franklin Pumptec Single-Phase Bore Pump Protection – 230V","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Franklin Pumptec is a motor-load monitoring and protection device designed specifically for compatible Franklin Electric 230V single-phase submersible bore-pump motors.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003ePumptec continuously monitors the motor load and electrical supply. It disconnects power when operating conditions indicate that the pump is running abnormally, helping protect the pump and motor from damage caused by low-water conditions and other underload faults.\u003c\/p\u003e\n\u003ch4\u003eWhat Pumptec protects against\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLow-yield or dry bores\u003c\/li\u003e\n\u003cli\u003eFalling bore water levels\u003c\/li\u003e\n\u003cli\u003eWorn pump components\u003c\/li\u003e\n\u003cli\u003eBroken pump shaft or coupling\u003c\/li\u003e\n\u003cli\u003eAir or gas locking\u003c\/li\u003e\n\u003cli\u003ePump cavitation\u003c\/li\u003e\n\u003cli\u003eLow supply voltage\u003c\/li\u003e\n\u003cli\u003eBlocked or clogged bore screens\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIndicator lights on the front show power, motor-load and voltage status without opening the enclosure. The underload sensitivity can be adjusted during commissioning to suit the installation.\u003c\/p\u003e\n\u003ch4\u003eCompatible pumps and motors\u003c\/h4\u003e\n\u003cp\u003ePumptec is suitable only for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin Electric two-wire single-phase submersible motors\u003c\/li\u003e\n\u003cli\u003eFranklin Electric three-wire single-phase submersible motors\u003c\/li\u003e\n\u003cli\u003eMotor sizes from 0.37kW to 1.1kW\u003c\/li\u003e\n\u003cli\u003e230V single-phase supply within Franklin’s stated ±10% voltage range\u003c\/li\u003e\n\u003cli\u003eCompatible Franklin FPS 240V two-wire bore pumps\u003c\/li\u003e\n\u003cli\u003eCompatible Franklin FPS 240V three-wire bore pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat is included\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin Pumptec motor-protection unit\u003c\/li\u003e\n\u003cli\u003eEnclosed protection relay\u003c\/li\u003e\n\u003cli\u003ePower, load and voltage indicator lights\u003c\/li\u003e\n\u003cli\u003eAdjustable underload sensitivity\u003c\/li\u003e\n\u003cli\u003eInternal motor-switching relay\u003c\/li\u003e\n\u003cli\u003eAlarm circuit contacts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat is not included\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBore pump or motor\u003c\/li\u003e\n\u003cli\u003eThree-wire motor control\/starter box\u003c\/li\u003e\n\u003cli\u003eSubmersible electrical drop cable\u003c\/li\u003e\n\u003cli\u003eWaterproof cable splice kit\u003c\/li\u003e\n\u003cli\u003eWater-level probes\u003c\/li\u003e\n\u003cli\u003ePressure switch or pressure controller\u003c\/li\u003e\n\u003cli\u003eFloat switch\u003c\/li\u003e\n\u003cli\u003eElectrical installation\u003c\/li\u003e\n\u003cli\u003eLightning arrestor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInstallation and selection warning\u003c\/h4\u003e\n\u003cblockquote\u003e\n\u003cp\u003eInstallation and commissioning must be completed by a licensed electrician. Confirm that the motor is a genuine Franklin Electric two-wire or three-wire 230V single-phase motor rated between 0.37kW and 1.1kW before ordering. The underload sensitivity and restart settings must be correctly adjusted for the bore and pumping system.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003ePumptec does not replace the correct Franklin control\/starter box required by a three-wire motor. The three-wire motor control box and Pumptec protection unit perform different functions and may both be required.\u003c\/p\u003e\n\u003cp\u003ePumptec is not suitable for Franklin three-wire permanent-split-capacitor motors, non-Franklin motors, motors above 1.1kW, 415V three-phase pumps, solar pumps or variable-speed systems. Use Pumptec Plus where broader single-phase motor compatibility or capacity up to 3.7kW is required.\u003c\/p\u003e\n\u003cp\u003ePumptec detects operating conditions through motor-load monitoring. It does not directly measure the bore water level and does not replace a water-level probe system where direct level control is required.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"Default Title","offer_id":43619661873200,"sku":null,"price":349.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Franklin-Pumptec-Single-Phase-Motor-Protection.jpg?v=1789458519"},{"product_id":"franklin-pumptec-plus-single-phase-pump-protection-230v-up-to-3-7kw","title":"Franklin Pumptec Plus Single-Phase Pump Protection – 230V up to 3.7kW","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Franklin Pumptec Plus is an advanced pump and motor-protection system for compatible 230V single-phase water-pump motors from 0.37kW to 3.7kW.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIt continuously monitors motor load and incoming voltage. When abnormal operating conditions are detected, Pumptec Plus disconnects the motor to help prevent damage and can automatically attempt a restart after the selected recovery period.\u003c\/p\u003e\n\u003cp\u003ePush-button Snapshot calibration records the pump’s normal operating load, while front-mounted indicator lights provide quick fault and operating-status information without opening the enclosure.\u003c\/p\u003e\n\u003ch4\u003eWhat Pumptec Plus protects against\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLow-yield or dry bores\u003c\/li\u003e\n\u003cli\u003eFalling bore water levels\u003c\/li\u003e\n\u003cli\u003eHigh and low supply voltage\u003c\/li\u003e\n\u003cli\u003eRapid pump cycling\u003c\/li\u003e\n\u003cli\u003ePower surges\u003c\/li\u003e\n\u003cli\u003eWorn pump components\u003c\/li\u003e\n\u003cli\u003eBroken pump shaft or coupling\u003c\/li\u003e\n\u003cli\u003eAir or gas locking\u003c\/li\u003e\n\u003cli\u003ePump cavitation\u003c\/li\u003e\n\u003cli\u003eBlocked bore screens\u003c\/li\u003e\n\u003cli\u003eSand or mud clogging\u003c\/li\u003e\n\u003cli\u003eFaulty check valves\u003c\/li\u003e\n\u003cli\u003eMotor overload and underload conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e230V single-phase operation\u003c\/li\u003e\n\u003cli\u003eSuitable for motors from 0.37kW to 3.7kW\u003c\/li\u003e\n\u003cli\u003ePush-button Snapshot calibration\u003c\/li\u003e\n\u003cli\u003eAdjustable automatic-restart timer\u003c\/li\u003e\n\u003cli\u003eContinuous calibration memory\u003c\/li\u003e\n\u003cli\u003eRun and fault indicator lights\u003c\/li\u003e\n\u003cli\u003eHeavy-duty 30-amp contactor\u003c\/li\u003e\n\u003cli\u003eHeavy-duty wiring terminals\u003c\/li\u003e\n\u003cli\u003eOverload and underload monitoring\u003c\/li\u003e\n\u003cli\u003eHigh-voltage and low-voltage monitoring\u003c\/li\u003e\n\u003cli\u003eRapid-cycle detection\u003c\/li\u003e\n\u003cli\u003eTransient surge protection\u003c\/li\u003e\n\u003cli\u003eLoad monitoring within ±25% of the field-calibrated setting\u003c\/li\u003e\n\u003cli\u003eFranklin Electric two-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatible pumps and motors\u003c\/h4\u003e\n\u003cp\u003ePumptec Plus is suitable for compatible:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-wire single-phase motors\u003c\/li\u003e\n\u003cli\u003eThree-wire single-phase motors\u003c\/li\u003e\n\u003cli\u003eThree-wire permanent-split-capacitor motors\u003c\/li\u003e\n\u003cli\u003eCapacitor-start\/capacitor-run motors\u003c\/li\u003e\n\u003cli\u003eCapacitor-start\/induction-run motors\u003c\/li\u003e\n\u003cli\u003eFranklin FPS 240V two-wire bore pumps\u003c\/li\u003e\n\u003cli\u003eFranklin FPS 240V three-wire bore pumps\u003c\/li\u003e\n\u003cli\u003eOther compatible 230V single-phase pump motors from 0.37kW to 3.7kW\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat is included\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin Pumptec Plus protection unit\u003c\/li\u003e\n\u003cli\u003eEnclosed heavy-duty 30-amp contactor\u003c\/li\u003e\n\u003cli\u003eLarge wiring terminal blocks\u003c\/li\u003e\n\u003cli\u003ePower, load and voltage indicator lights\u003c\/li\u003e\n\u003cli\u003ePush-button Snapshot calibration\u003c\/li\u003e\n\u003cli\u003eAdjustable automatic-restart timer\u003c\/li\u003e\n\u003cli\u003eInternal surge protection\u003c\/li\u003e\n\u003cli\u003eWall-mounting enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat is not included\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePump or motor\u003c\/li\u003e\n\u003cli\u003eThree-wire motor capacitor\/control box\u003c\/li\u003e\n\u003cli\u003eSubmersible electrical drop cable\u003c\/li\u003e\n\u003cli\u003eWaterproof cable splice kit\u003c\/li\u003e\n\u003cli\u003eWater-level probes\u003c\/li\u003e\n\u003cli\u003ePressure switch or pressure controller\u003c\/li\u003e\n\u003cli\u003eFloat switch\u003c\/li\u003e\n\u003cli\u003eExternal lightning arrestor\u003c\/li\u003e\n\u003cli\u003eElectrical installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInstallation and selection warning\u003c\/h4\u003e\n\u003cblockquote\u003e\n\u003cp\u003eInstallation and commissioning must be completed by a licensed electrician. Confirm that the motor is 230V single phase, uses a compatible motor design and is rated between 0.37kW and 3.7kW. The unit must be calibrated while the pump is operating under normal hydraulic load.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003eIncorrect calibration or restart settings can cause nuisance tripping or reduce the protection provided. The restart delay should allow sufficient time for a low-yield bore to recover before the pump restarts.\u003c\/p\u003e\n\u003cp\u003ePumptec Plus does not replace the correct Franklin capacitor\/control box required by a three-wire submersible motor. The control box starts the motor, while Pumptec Plus monitors and protects the complete pumping system.\u003c\/p\u003e\n\u003cp\u003ePumptec Plus detects water-related faults indirectly through motor-load changes. It does not directly measure water level and does not replace a probe or float system where direct bore or tank-level control is required.\u003c\/p\u003e\n\u003cp\u003eIt is not suitable for 415V three-phase motors, solar pumps or variable-speed pump systems.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"Default Title","offer_id":43619664035888,"sku":null,"price":699.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Franklin-Pumptec-Plus-Single-Phase-Motor-Protection.jpg?v=1789458767"},{"product_id":"franklin-fds-digital-automatic-pump-controller","title":"Franklin FDS Digital Automatic Pump Controller","description":"\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eFranklin FDS Digital Automatic Pump Controller\u003c\/strong\u003e is an inline automatic pressure controller and pump-protection device for compatible 230V single-phase water pumps up to 2.2kW and 16 amps.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIt automatically starts the pump when system pressure falls and stops it when water demand ends. Unlike a basic press-control unit, the FDS allows the starting pressure and outlet pressure to be independently adjusted, helping provide stable water pressure throughout the system.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe digital display shows outlet pressure and motor-current information. Integrated pressure, flow and current sensors protect the pump against dry running, excessive current, overpressure and rotor blockage.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable starting pressure from 0.5 to 5.5 bar\u003c\/li\u003e\n\u003cli\u003eAdjustable outlet pressure from 2 to 6 bar\u003c\/li\u003e\n\u003cli\u003eStable outlet-pressure regulation within approximately ±0.5 bar\u003c\/li\u003e\n\u003cli\u003eDigital pressure gauge displaying bar or psi\u003c\/li\u003e\n\u003cli\u003eReal-time motor-current display\u003c\/li\u003e\n\u003cli\u003eIntegrated pressure, flow and current sensors\u003c\/li\u003e\n\u003cli\u003eDry-running protection with automatic restart attempts\u003c\/li\u003e\n\u003cli\u003eOvercurrent, overpressure and rotor-blockage protection\u003c\/li\u003e\n\u003cli\u003eConfigurable maximum continuous-running protection\u003c\/li\u003e\n\u003cli\u003eAutomatic anti-blocking cycle after prolonged inactivity\u003c\/li\u003e\n\u003cli\u003eOperating data and alarm logging\u003c\/li\u003e\n\u003cli\u003eBuilt-in check valve and small storage diaphragm\u003c\/li\u003e\n\u003cli\u003eCommunication mode for correctly designed two-pump booster systems\u003c\/li\u003e\n\u003cli\u003eIP65 enclosure\u003c\/li\u003e\n\u003cli\u003eMaximum working pressure of 12 bar\u003c\/li\u003e\n\u003cli\u003eMaximum water temperature of 50°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eCompatible pumps and applications\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eSuitable for correctly selected:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin MH 230V single-phase horizontal multistage pumps\u003c\/li\u003e\n\u003cli\u003eFranklin EVR 230V single-phase vertical multistage pumps\u003c\/li\u003e\n\u003cli\u003eOther compatible 230V single-phase surface pumps\u003c\/li\u003e\n\u003cli\u003ePumps rated at no more than 2.2kW and 16 amps\u003c\/li\u003e\n\u003cli\u003eDomestic household pressure systems\u003c\/li\u003e\n\u003cli\u003eRainwater supply systems\u003c\/li\u003e\n\u003cli\u003eRural water-pressure systems\u003c\/li\u003e\n\u003cli\u003eGarden irrigation\u003c\/li\u003e\n\u003cli\u003eWater transfer and pressure boosting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eIt is not suitable for three-phase pumps, solar-direct pumps, pumps controlled by a variable-speed drive, or motors exceeding 2.2kW or 16 amps.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eWhat is included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Franklin FDS controller\u003c\/li\u003e\n\u003cli\u003eDigital display\u003c\/li\u003e\n\u003cli\u003eIntegrated pressure, flow and current sensors\u003c\/li\u003e\n\u003cli\u003eBuilt-in check valve\u003c\/li\u003e\n\u003cli\u003eBuilt-in storage diaphragm\u003c\/li\u003e\n\u003cli\u003eIntegrated automatic pump-protection functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eWhat is not included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater pump\u003c\/li\u003e\n\u003cli\u003eExternal pressure tank\u003c\/li\u003e\n\u003cli\u003ePipe unions, reducers or plumbing fittings\u003c\/li\u003e\n\u003cli\u003eIsolation valves\u003c\/li\u003e\n\u003cli\u003eElectrical circuit protection\u003c\/li\u003e\n\u003cli\u003eWater-level probes\u003c\/li\u003e\n\u003cli\u003eSecond pump or second controller for twin-pump operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eInstallation and selection warning\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Franklin FDS is \u003cstrong\u003enot a variable-speed drive\u003c\/strong\u003e and does not change the speed of the pump motor. It controls pump starting and stopping and regulates the outlet pressure through its integrated control system.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eBefore ordering, confirm that the pump is 230V single phase, no larger than 2.2kW and has a motor full-load current no higher than 16 amps. Both the motor power and current limits must be checked.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe selected outlet pressure must be within the pump’s actual operating capability after allowing for suction lift, pumping water level, elevation and pipe-friction losses. Setting the controller above the pump’s available pressure will not increase pump performance and may cause continuous operation or repeated faults.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eInstall the FDS in the correct flow direction and select the 25mm or 32mm model to suit the system pipework. Maximum operating pressure is 12 bar and maximum water temperature is 50°C. The IP65 enclosure is not suitable for immersion or flooding.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eElectrical installation must be completed by a licensed electrician. The built-in dry-running protection does not replace direct tank or bore water-level protection where positive level control is required.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"Franklin FDS Digital Automatic Pump Controller – 25mm","offer_id":43620127014960,"sku":null,"price":259.0,"currency_code":"AUD","in_stock":true},{"title":"Franklin FDS Digital Automatic Pump Controller – 32mm","offer_id":43620127047728,"sku":null,"price":409.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Franklin-FDS-Digital-Pump-Controller.jpg?v=1789469183"},{"product_id":"franklin-resimatic-art-automatic-pump-controller","title":"Franklin Resimatic ART Automatic Pump Controller","description":"\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eFranklin Resimatic ART Automatic Pump Controller\u003c\/strong\u003e provides automatic start-and-stop control and dry-running protection for compatible 230V single-phase water pumps up to 1.5kW and 10 amps.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe Resimatic monitors both system pressure and water flow. Opening a tap causes the controller to start the pump automatically. When demand finishes and flow stops, the controller shuts the pump down after approximately 10 seconds.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eStarting pressure is adjustable between 1.5 and 3 bar, allowing the controller to be matched to the requirements of the pump and water system. An integrated pressure gauge allows the system pressure to be checked during installation and operation.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe ART Automatic Reset Test function periodically attempts to restart the pump after a dry-running shutdown. This allows the system to resume operating automatically when the water supply returns, without requiring an immediate manual reset.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic pump starting and stopping\u003c\/li\u003e\n\u003cli\u003eAdjustable starting pressure from 1.5 to 3 bar\u003c\/li\u003e\n\u003cli\u003eIntegrated pressure and flow sensors\u003c\/li\u003e\n\u003cli\u003eDry-running protection\u003c\/li\u003e\n\u003cli\u003eAutomatic restart attempts after a dry-running shutdown\u003c\/li\u003e\n\u003cli\u003eIntegrated pressure gauge\u003c\/li\u003e\n\u003cli\u003eIntegrated small accumulation system\u003c\/li\u003e\n\u003cli\u003eHelps prevent frequent cycling from dripping taps or minor leaks\u003c\/li\u003e\n\u003cli\u003eProtection against water hammer\u003c\/li\u003e\n\u003cli\u003eManual restart button\u003c\/li\u003e\n\u003cli\u003ePower, pump-running and fault indicator lights\u003c\/li\u003e\n\u003cli\u003eIP65 enclosure\u003c\/li\u003e\n\u003cli\u003eMaximum working pressure of 10 bar\u003c\/li\u003e\n\u003cli\u003eMaximum water temperature of 50°C\u003c\/li\u003e\n\u003cli\u003eMaximum pump motor rating of 1.5kW\u003c\/li\u003e\n\u003cli\u003eMaximum rated current of 10 amps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eCompatible pumps and applications\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eSuitable for correctly selected:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin MH 230V single-phase horizontal multistage pumps\u003c\/li\u003e\n\u003cli\u003eOther compatible 230V single-phase surface pumps\u003c\/li\u003e\n\u003cli\u003eCompatible single-phase submersible pump systems\u003c\/li\u003e\n\u003cli\u003eDomestic household pressure systems\u003c\/li\u003e\n\u003cli\u003eRainwater supply systems\u003c\/li\u003e\n\u003cli\u003eRural water systems\u003c\/li\u003e\n\u003cli\u003eGarden irrigation\u003c\/li\u003e\n\u003cli\u003eWater transfer and pressure boosting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe factory lead-fitted versions are specifically supplied with plug-and-play leads for compatible Franklin MH pump builds.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eCompatibility with Franklin EVR pumps or other pump ranges must be confirmed against the motor current, motor power, electrical connection and required system pressure before ordering.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eWhat is included\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eAll variants include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Franklin Resimatic ART controller\u003c\/li\u003e\n\u003cli\u003eIntegrated pressure and flow sensing\u003c\/li\u003e\n\u003cli\u003eIntegrated pressure gauge\u003c\/li\u003e\n\u003cli\u003eIntegrated small accumulation system\u003c\/li\u003e\n\u003cli\u003eAutomatic Reset Test dry-running protection\u003c\/li\u003e\n\u003cli\u003eManual restart button and indicator lights\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe lead-fitted variants also include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFactory-fitted cable\u003c\/li\u003e\n\u003cli\u003ePlug-and-play electrical leads for compatible Franklin MH pump builds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eWhat is not included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater pump\u003c\/li\u003e\n\u003cli\u003ePipe unions, reducers or plumbing fittings\u003c\/li\u003e\n\u003cli\u003eIsolation valves\u003c\/li\u003e\n\u003cli\u003eSeparate electrical circuit protection\u003c\/li\u003e\n\u003cli\u003eLarge external pressure tank\u003c\/li\u003e\n\u003cli\u003eWater-level probes\u003c\/li\u003e\n\u003cli\u003eInstallation labour\u003c\/li\u003e\n\u003cli\u003ePlug-and-play leads with the standard non-lead variants\u003c\/li\u003e\n\u003cli\u003eReplacement electronic board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eInstallation and selection warning\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Franklin Resimatic ART is \u003cstrong\u003enot a variable-speed controller\u003c\/strong\u003e and does not regulate the motor speed or maintain a selected outlet pressure. It automatically starts and stops the pump using pressure and flow sensing.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe pump must be 230V single phase, no larger than 1.5kW and have a full-load current no higher than 10 amps. Both the motor power and current limits must be checked before installation.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe adjustable starting pressure must be set below the pressure the pump can reliably produce after allowing for suction lift, pumping water level, elevation and pipe-friction losses. An incorrectly selected starting pressure can prevent the pump from starting correctly or cause unreliable operation.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eMaximum working pressure is 10 bar and maximum water temperature is 50°C. The IP65 enclosure is not designed for immersion or flooding. Install the controller in the correct flow direction and provide suitable isolation and service access.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eElectrical installation of the standard non-lead versions must be completed by a licensed electrician. The dry-running protection does not replace direct tank or bore water-level protection where positive level control is required.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eTechnical information is confirmed by Franklin Electric’s \u003ca rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/franklinwater.eu\/products\/surface-pumps\/accessories\/franklin-pump-accessories\/resimatic-art\/?utm_source=chatgpt.com\"\u003eResimatic ART product information\u003c\/a\u003e.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"Franklin Resimatic ART Automatic Pump Controller – 25mm","offer_id":43623062798384,"sku":null,"price":219.0,"currency_code":"AUD","in_stock":true},{"title":"Franklin Resimatic ART Automatic Pump Controller – 32mm","offer_id":43623062831152,"sku":null,"price":289.0,"currency_code":"AUD","in_stock":true},{"title":"Franklin Resimatic ART Automatic Pump Controller with Plug-and-Play Leads – 25mm","offer_id":43623062863920,"sku":null,"price":289.0,"currency_code":"AUD","in_stock":true},{"title":"Franklin Resimatic ART Automatic Pump Controller with Plug-and-Play Leads – 32mm","offer_id":43623062896688,"sku":null,"price":379.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Franklin-Resimatic-ART-Automatic-Pump-Controller.jpg?v=1789522033"},{"product_id":"telemecanique-xmpa12c2142-adjustable-pump-pressure-switch-standard-or-with-ip67-plug-leads","title":"Telemecanique XMPA12C2142 Adjustable Pump Pressure Switch – Standard or With IP67 Plug Leads","description":"\u003cp\u003eThe \u003cstrong\u003eTelemecanique XMPA12C2142 Adjustable Pump Pressure Switch\u003c\/strong\u003e automatically starts and stops a compatible water pump according to system pressure.\u003c\/p\u003e\n\u003cp\u003eThis is a genuine Telemecanique pressure switch listed by Franklin Electric Australia as a compatible accessory for Franklin MH pressure-pump systems. It is a third-party compatible product and is not manufactured by Franklin Electric.\u003c\/p\u003e\n\u003cp\u003eWhen system pressure falls to the selected starting pressure, the switch closes the pump-control circuit. When pressure reaches the selected stopping pressure, the switch opens the circuit and stops the pump.\u003c\/p\u003e\n\u003cp\u003eThe switch has three normally closed snap-action contacts and can be incorporated into correctly designed single-phase or three-phase pump systems. It is also compatible with the pressure-switch control input provided in Franklin CP1 and CP3 control panels.\u003c\/p\u003e\n\u003ch3\u003eAvailable variants\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTelemecanique XMPA12C2142 Adjustable Pressure Switch – Standard:\u003c\/strong\u003e Supplied as an unwired pressure switch for installation by a licensed electrician.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTelemecanique XMPA12C2142 Adjustable Pressure Switch – With Two IP67 Plug Leads:\u003c\/strong\u003e Supplied with two fitted male and female plug leads for easier connection to compatible Franklin MH pump installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic pressure-based pump starting and stopping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable starting and stopping pressures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRegulation between two pressure thresholds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFalling-pressure switching adjustment from 0.3 to 10.3 bar\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUpper-pressure adjustment from 1.3 to 12 bar\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum pressure rating of 12 bar\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable pressure differential\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThree normally closed snap-action contacts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSix electrical terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e¼-inch BSP female pressure connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for fresh water, seawater and air from 0°C to 70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum operating rate of 10 cycles per minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP54 pressure-switch enclosure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailable with or without two IP67 male and female plug leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible pumps and applications\u003c\/h3\u003e\n\u003cp\u003eSuitable for correctly designed:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFranklin MH 230V single-phase pressure-pump systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFranklin MH 415V three-phase pressure-pump systems using an appropriate control panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFranklin CP1 single-phase control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFranklin CP3 three-phase control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible surface pressure pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure-tank pump systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDomestic and rural water-pressure systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIrrigation and water-transfer installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatibility must be confirmed from the pump motor rating, starting method and control-panel arrangement. This switch should not be treated as universally compatible with every Franklin pump.\u003c\/p\u003e\n\u003ch3\u003eWhat is included\u003c\/h3\u003e\n\u003cp\u003eThe standard variant includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTelemecanique XMPA12C2142 pressure switch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective enclosure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable pressure and differential mechanism\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThree normally closed contacts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo cable-entry positions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe lead-fitted variant includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTelemecanique XMPA12C2142 pressure switch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo fitted IP67 male and female plug leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective enclosure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable pressure and differential mechanism\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThree normally closed contacts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat is not included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWater pump\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFranklin CP1 or CP3 control panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure tank\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure gauge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFive-way connector or pressure manifold\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-return valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlumbing adaptors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotor-overload protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDry-running or water-level protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical or plumbing installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and selection warning\u003c\/h3\u003e\n\u003cp\u003eThis pressure switch provides pressure-based pump starting and stopping only. It does not provide motor-overload, dry-running, no-flow or water-level protection. These functions require a compatible control panel or separate protection device.\u003c\/p\u003e\n\u003cp\u003eThe pump motor, contactor, control panel and pressure switch must be checked for electrical compatibility before installation. Direct switching of a pump motor must not be assumed solely from the voltage or maximum pressure rating.\u003c\/p\u003e\n\u003cp\u003eThe starting and stopping pressures must be matched to the pump’s actual performance after allowing for suction conditions, elevation and pipe-friction losses. Setting the stopping pressure above the pressure the pump can produce may cause continuous operation.\u003c\/p\u003e\n\u003cp\u003eA suitably sized pressure tank must be installed and correctly pre-charged in relation to the starting pressure. Incorrect pressure settings, insufficient tank capacity or incorrect tank pre-charge can cause rapid pump cycling and premature motor damage.\u003c\/p\u003e\n\u003cp\u003eThe switch enclosure is rated IP54. The plug connectors supplied with the lead-fitted version are IP67, but this does not increase the pressure switch enclosure above IP54. Install the switch in a protected and accessible location away from flooding, direct weather exposure and pipe strain.\u003c\/p\u003e\n\u003cp\u003eElectrical installation and pressure-switch adjustment must be completed by a licensed electrician or appropriately qualified pump technician.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"Telemecanique XMPA12C2142 Adjustable Pressure Switch – Standard","offer_id":43623099433008,"sku":null,"price":99.0,"currency_code":"AUD","in_stock":true},{"title":"Telemecanique XMPA12C2142 Adjustable Pressure Switch – With Two IP67 Plug Leads","offer_id":43623099465776,"sku":null,"price":139.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Telemecanique-XMPA12C2142-Pressure-Switch.png?v=1789522522"},{"product_id":"franklin-blc-water-level-probe-relay-factory-fitted-cp1-cp3-panel-option","title":"Franklin BLC Water-Level Probe Relay – Factory-Fitted CP1 \u0026 CP3 Panel Option","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFranklin BLC Water-Level Probe Relay\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a factory-fitted control-panel option that allows compatible Franklin LP2W water-level probes to control or protect a water pump according to the water level in a tank, bore or water source.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe BLC accepts signals from either one or two conductivity probes. Depending on the panel configuration and probe placement, it can be used to stop a pump when the source water falls below a safe level or provide automatic control between selected water levels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis is not a standalone external controller. The BLC must be ordered as a factory-fitted option inside a compatible Franklin CP1 single-phase or CP3 three-phase control panel.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFactory-fitted water-level probe relay\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for one or two Franklin LP2W probes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides water-level input to the pump-control panel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCan be configured for low-level pump protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCan provide single-level or two-level control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for tank, bore and water-source level monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstalled and wired inside the selected control panel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible with Franklin CP1 and CP3 full control panels\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eCompatible pumps and applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe BLC option can be used with pumps controlled by:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFranklin CP1 230V single-phase control panels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFranklin CP3 415V three-phase control panels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCorrectly selected Franklin FPS bore pumps\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible Franklin MH and EVR pumps using a CP1 or CP3 panel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTank-filling systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBore-water level protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-yield bore installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuction tanks and water-storage systems\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe control panel must be correctly sized for the connected pump motor. The BLC does not determine the electrical size of the panel.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRequired probes\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe BLC requires either one or two compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFranklin LP2W two-wire stainless-steel water-level probes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProbe choice depends on the application:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOne probe:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Used where a single water-level switching point is required.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTwo probes:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Used where separate upper and lower water levels are required.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLP2W probes are available separately in cable lengths from 20 metres to 200 metres.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFranklin BLC probe relay\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFactory installation inside the selected CP1 or CP3 control panel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternal control-panel wiring for the ordered configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is not included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCP1 or CP3 control panel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLP2W water-level probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProbe cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWater pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrical supply wiring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExternal junction boxes or cable glands\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOn-site installation or commissioning\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eInstallation and selection warning\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe BLC is a factory-fitted control-panel option and must be ordered with a compatible Franklin CP1 or CP3 full control panel. It should not be ordered as a loose standalone relay or installed without a suitable protective enclosure and correctly designed control circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe number of probes and required control function must be confirmed before the panel is ordered. Probe positioning determines the levels at which the pump starts or stops.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe BLC does not replace the panel’s motor-overload protection and does not directly power the pump. It provides a level-control signal to the control panel.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLP2W conductivity probes must never be subjected to high-voltage insulation or “Megger” testing, as this may damage the probe circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe control panel must be selected to match the pump voltage, phase, motor power and full-load current. Installation, probe wiring and commissioning must be completed by a licensed electrician or qualified pump technician.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFactory-fitted options have an estimated lead time of approximately two to three weeks, subject to Franklin availability.\u003c\/span\u003e\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"Default Title","offer_id":43623113654320,"sku":null,"price":285.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Franklin-BLC-Probe-Relay-Factory-Fitted-Option.jpg?v=1789523010"},{"product_id":"franklin-lp2w-two-wire-rubber-cased-water-level-probe-20m-to-200m","title":"Franklin LP2W Two-Wire Rubber-Cased Water-Level Probe – 20m to 200m","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Franklin LP2W is a two-wire conductivity probe designed for water-level sensing in bores, tanks and other clean-water applications. Its two sensing wires are enclosed within a durable rubber casing, with the selected cable length permanently attached for installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eConnected to compatible control equipment, the probe detects whether water is present at its installed position. It can be used to help protect a pump from dry running, control tank filling or manage automatic pump start and stop levels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eCompatible applications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBore-water level monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTank filling and emptying systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-water pump protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-level and low-level water control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFranklin CP1 single-phase control panels fitted with a compatible BLC water-level relay\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFranklin CP3 three-phase control panels fitted with a compatible BLC water-level relay\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible Franklin BLC, LP2R and LCP water-level control equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe LP2W is a sensing probe only. It does not switch a pump motor directly and must be connected to compatible control equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAvailable cable lengths\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e20 metres\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e30 metres\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e40 metres\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e50 metres\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e60 metres\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e70 metres\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e80 metres\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e90 metres\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e100 metres\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e120 metres\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e140 metres\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e160 metres\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e180 metres\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e200 metres\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eProbe quantity options\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSingle probe – one LP2W probe and attached cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwin probe set – two matching LP2W probes with separate attached cables\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA twin probe set uses two individual LP2W probes positioned at different levels. It is not a separate Franklin probe model.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWhat is included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSelected quantity of Franklin LP2W two-wire rubber-cased water-level probes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFactory-attached cable in the selected length\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eNot included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBLC, LP2R or other water-level control relay\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCP1 or CP3 pump control panel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePump, motor or starter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eJunction boxes, cable glands or additional cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstallation or electrical connection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation and selection warning\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSelect a cable length that reaches from the required sensing position to the control panel or approved junction point without placing strain on the probe or cable. Cable length must be confirmed before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe brown or black wire marked number 8 and the blue wire marked number 1 must be connected to the correct terminals specified by the compatible controller’s wiring diagram.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDo not connect the LP2W directly to a pump motor or mains electricity. Do not subject the probe circuit to high-voltage insulation or Megger testing, as this can damage the sensing equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstallation and electrical connection must be completed by a suitably qualified person in accordance with the controller instructions and applicable Australian electrical requirements. Confirm water conductivity, required control function and controller compatibility before ordering.\u003c\/span\u003e\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"20m","offer_id":43623184924720,"sku":null,"price":189.0,"currency_code":"AUD","in_stock":true},{"title":"30m","offer_id":43623184957488,"sku":null,"price":209.0,"currency_code":"AUD","in_stock":true},{"title":"40m","offer_id":43623184990256,"sku":null,"price":239.0,"currency_code":"AUD","in_stock":true},{"title":"50m","offer_id":43623185023024,"sku":null,"price":259.0,"currency_code":"AUD","in_stock":true},{"title":"60m","offer_id":43623185055792,"sku":null,"price":289.0,"currency_code":"AUD","in_stock":true},{"title":"70m","offer_id":43623185088560,"sku":null,"price":319.0,"currency_code":"AUD","in_stock":true},{"title":"80m","offer_id":43623185121328,"sku":null,"price":339.0,"currency_code":"AUD","in_stock":true},{"title":"90m","offer_id":43623185154096,"sku":null,"price":359.0,"currency_code":"AUD","in_stock":true},{"title":"100m","offer_id":43623185186864,"sku":null,"price":389.0,"currency_code":"AUD","in_stock":true},{"title":"120m","offer_id":43623185219632,"sku":null,"price":439.0,"currency_code":"AUD","in_stock":true},{"title":"140m","offer_id":43623185252400,"sku":null,"price":489.0,"currency_code":"AUD","in_stock":true},{"title":"160m","offer_id":43623185285168,"sku":null,"price":539.0,"currency_code":"AUD","in_stock":true},{"title":"180m","offer_id":43623185317936,"sku":null,"price":589.0,"currency_code":"AUD","in_stock":true},{"title":"200m","offer_id":43623185350704,"sku":null,"price":649.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Franklin-LP2W-Water-Level-Probe_1.jpg?v=1789524394"},{"product_id":"kelco-k-series-heavy-duty-tank-float-switch-4m-to-50m-cable","title":"Kelco K Series Heavy-Duty Tank Float Switch – 4m to 50m Cable","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Australian-made Kelco K Series is a heavy-duty, three-wire float switch designed for accurate single-point water-level sensing in tanks, sumps and pump systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts low-differential switching action changes state with approximately 35mm of water-level movement, making it suitable for high-level alarms, low-level pump protection and accurate single-point filling or emptying control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe polypropylene float is attached to a durable rubber-clad three-core cable. Its sealed construction contains no mercury or lead and is suitable for potable water, bore water, seawater and many wastewater applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWhat the float switch does\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDetects when water reaches or falls below its installed position\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides a normally open or normally closed switching signal\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCan signal a pump to start or stop\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCan be wired for tank filling or tank emptying\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides low-water pump protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides high-level or low-level alarm signalling\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDoes not require a Franklin BLC probe relay\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eCompatible pumps and applications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Kelco K Series can be used with Franklin MH and EVR pumps, Franklin bore pumps and other suitable pump systems when connected through a compatible control panel, relay or contactor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSuitable applications include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eRainwater and storage tanks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBore-water storage systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTank filling or emptying control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-water pump protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-level and low-level alarms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSumps and wastewater systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePotable-water systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible Franklin CP1 and CP3 control panels with a suitable float-switch input\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAvailable cable lengths\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eK4M – Kelco K Series float switch with 4-metre attached cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eK6M – Kelco K Series float switch with 6-metre attached cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eK10M – Kelco K Series float switch with 10-metre attached cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eK20M – Kelco K Series float switch with 20-metre attached cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eK30M – Kelco K Series float switch with 30-metre attached cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eK50M – Kelco K Series float switch with 50-metre attached cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe stated measurement is the total attached cable length.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWhat is included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOne Kelco K Series three-wire float switch\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFactory-attached cable in the selected length\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eNot included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eKelco split-style cable weight\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFranklin CP1 or CP3 control panel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRelay, contactor or motor starter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePump or motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eJunction box, cable glands or additional cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrical installation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation and selection warning\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe K Series is a low-differential, single-point float switch. One switch can provide a filling or emptying signal, but it does not provide a wide separation between pump start and stop levels. Applications requiring separate high and low switching points generally require two K Series switches, suitable control equipment or a Kelco Q Series high-differential float switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Franklin-supplied K Series is listed as a 10-amp resistive, 0–240-volt single-pole double-throw switch. A resistive rating must not be treated as an equivalent pump-motor rating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDo not connect the float switch directly to a three-phase motor. Pump motors and loads exceeding the switch’s appropriate electrical rating must be operated through a correctly selected control panel, relay or contactor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAllow at least 150mm of free cable between the float and its tethering point. Install the float at least 100mm away from tank walls, pipes and other equipment so it can move freely. Avoid turbulence, cable abrasion and prolonged direct sunlight.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe switch must not be used deeper than 30 metres, in closed vessels above 300kPa, in liquids below −20°C or above 60°C, or in liquids with a specific gravity below 0.82 without confirming suitability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAll mains-voltage wiring must be completed by a licensed electrician in accordance with the supplied Kelco instructions and applicable Australian electrical requirements.\u003c\/span\u003e\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"K4M – 4-metre cable \/ Yes","offer_id":43623236567088,"sku":null,"price":205.0,"currency_code":"AUD","in_stock":true},{"title":"K4M – 4-metre cable \/ No","offer_id":43623236599856,"sku":null,"price":155.0,"currency_code":"AUD","in_stock":true},{"title":"K6M – 6-metre cable \/ Yes","offer_id":43623236632624,"sku":null,"price":225.0,"currency_code":"AUD","in_stock":true},{"title":"K6M – 6-metre cable \/ No","offer_id":43623236665392,"sku":null,"price":175.0,"currency_code":"AUD","in_stock":true},{"title":"K10M – 10-metre cable \/ Yes","offer_id":43623236698160,"sku":null,"price":249.0,"currency_code":"AUD","in_stock":true},{"title":"K10M – 10-metre cable \/ No","offer_id":43623236730928,"sku":null,"price":199.0,"currency_code":"AUD","in_stock":true},{"title":"K20M – 20-metre cable \/ Yes","offer_id":43623236763696,"sku":null,"price":330.0,"currency_code":"AUD","in_stock":true},{"title":"K20M – 20-metre cable \/ No","offer_id":43623236796464,"sku":null,"price":280.0,"currency_code":"AUD","in_stock":true},{"title":"K30M – 30-metre cable \/ Yes","offer_id":43623236829232,"sku":null,"price":405.0,"currency_code":"AUD","in_stock":true},{"title":"K30M – 30-metre cable \/ No","offer_id":43623236862000,"sku":null,"price":355.0,"currency_code":"AUD","in_stock":true},{"title":"K50M – 50-metre cable \/ Yes","offer_id":43623236894768,"sku":null,"price":525.0,"currency_code":"AUD","in_stock":true},{"title":"K50M – 50-metre cable \/ No","offer_id":43623236927536,"sku":null,"price":475.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Kelco-K-Series-Heavy-Duty-Float-Switch.png?v=1789524973"},{"product_id":"kelco-q-series-heavy-duty-tank-float-switch-4m-to-50m-cable","title":"Kelco Q Series Heavy-Duty Tank Float Switch – 4m to 50m Cable","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Australian-made Kelco Q Series is a heavy-duty, three-wire float switch designed for automatic tank filling, tank emptying, pump protection and liquid-level control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUnlike the low-differential Kelco K Series, the Q Series provides two-position switching. Correctly tethering the cable creates separate pump start and stop levels, with an approximate operating differential between 170mm and 300mm in water.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe heavy-duty polypropylene float is double-moulded onto a durable three-core rubber cable. It contains no mercury or lead and has no corrodible metal parts exposed to the liquid.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWhat the float switch does\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAutomatically starts or stops a pump according to water level\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCan be wired for tank filling or tank emptying\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides separate pump start and stop levels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProtects pumps against low water or loss of prime\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eControls sump-pump operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides high-level or low-level alarm signalling\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCan provide a signal to a control panel, relay or programmable logic controller\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDoes not require a Franklin BLC probe relay\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eCompatible pumps and applications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Kelco Q Series can be used with Franklin MH and EVR pumps, Franklin bore pumps and other suitable pumping systems when correctly connected through a compatible control panel, relay or contactor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSuitable applications include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eRainwater and storage tanks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBore-water storage systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTank filling and tank emptying\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePump dry-run and loss-of-prime protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSumps, pits and dams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePotable-water systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWastewater and effluent systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible Franklin CP1 and CP3 control panels with a suitable float-switch input\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAvailable cable lengths\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eQ4M – Kelco Q Series float switch with 4-metre attached cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQ6M – Kelco Q Series float switch with 6-metre attached cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQ10M – Kelco Q Series float switch with 10-metre attached cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQ15M – Kelco Q Series float switch with 15-metre attached cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQ20M – Kelco Q Series float switch with 20-metre attached cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQ30M – Kelco Q Series float switch with 30-metre attached cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQ50M – Kelco Q Series float switch with 50-metre attached cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe stated measurement is the total attached cable length.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWhat is included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOne Kelco Q Series three-wire float switch\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFactory-attached cable in the selected length\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eNot included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eKelco QCW split-style cable weight\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFranklin control panel or probe relay\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRelay, contactor or motor starter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePump or motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eJunction box, cable glands or additional cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrical installation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation and selection warning\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Q Series provides an approximate switching differential of 170mm to 300mm in water. The actual difference between pump start and stop levels depends on how the cable is tethered. Applications requiring more than 300mm between switching levels generally require two float switches and suitable relay control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe float requires sufficient room to move freely and is not recommended for vessels or wells narrower than approximately 600mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe switch is rated at 21 amps for resistive loads but only 4 amps for alternating-current motor loads. Do not select it using the 21-amp resistive rating when controlling a pump motor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDo not connect the float switch directly to a three-phase motor. Franklin pumps and other loads exceeding the correct motor-load rating must be operated through a suitably selected control panel, relay or contactor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eKeep the tethering point or optional cable weight at least 100mm from the float’s cable boot. Install away from turbulence, tank walls, pipework and moving equipment to prevent abrasion, tangling or restricted movement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe switch must not be used deeper than 30 metres, in closed vessels above 300kPa, in liquids below −20°C or above 60°C, or in liquids with a specific gravity below 0.82 without confirming suitability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhere practical, use a low-voltage control circuit. All mains-voltage wiring must be completed by a licensed electrician in accordance with Kelco’s instructions and applicable Australian electrical requirements.\u003c\/span\u003e\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"Q4M – 4-metre cable \/ Yes","offer_id":43623264092208,"sku":null,"price":225.0,"currency_code":"AUD","in_stock":true},{"title":"Q4M – 4-metre cable \/ No","offer_id":43623264124976,"sku":null,"price":175.0,"currency_code":"AUD","in_stock":true},{"title":"Q6M – 6-metre cable \/ Yes","offer_id":43623264157744,"sku":null,"price":245.0,"currency_code":"AUD","in_stock":true},{"title":"Q6M – 6-metre cable \/ No","offer_id":43623264190512,"sku":null,"price":195.0,"currency_code":"AUD","in_stock":true},{"title":"Q10M – 10-metre cable \/ Yes","offer_id":43623264223280,"sku":null,"price":305.0,"currency_code":"AUD","in_stock":true},{"title":"Q10M – 10-metre cable \/ No","offer_id":43623264256048,"sku":null,"price":255.0,"currency_code":"AUD","in_stock":true},{"title":"Q15M – 15-metre cable \/ Yes","offer_id":43623264288816,"sku":null,"price":375.0,"currency_code":"AUD","in_stock":true},{"title":"Q15M – 15-metre cable \/ No","offer_id":43623264321584,"sku":null,"price":325.0,"currency_code":"AUD","in_stock":true},{"title":"Q20M – 20-metre cable \/ Yes","offer_id":43623264354352,"sku":null,"price":480.0,"currency_code":"AUD","in_stock":true},{"title":"Q20M – 20-metre cable \/ No","offer_id":43623264387120,"sku":null,"price":430.0,"currency_code":"AUD","in_stock":true},{"title":"Q30M – 30-metre cable \/ Yes","offer_id":43623264419888,"sku":null,"price":605.0,"currency_code":"AUD","in_stock":true},{"title":"Q30M – 30-metre cable \/ No","offer_id":43623264452656,"sku":null,"price":555.0,"currency_code":"AUD","in_stock":true},{"title":"Q50M – 50-metre cable \/ Yes","offer_id":43623264485424,"sku":null,"price":825.0,"currency_code":"AUD","in_stock":true},{"title":"Q50M – 50-metre cable \/ No","offer_id":43623264518192,"sku":null,"price":775.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Kelco-Q-Series-Heavy-Duty-Float-Switch.png?v=1789525885"},{"product_id":"kelco-c25-inline-flow-switch","title":"Kelco C25 Inline Flow Switch","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Australian-made Kelco C25 is a compact 25mm inline flow switch designed to detect water flow through pump discharge pipework.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA magnetically actuated internal piston operates a normally open dry-contact switch when flow begins. The signal can be connected to a compatible pump-control panel, relay or programmable controller for flow monitoring and no-flow pump protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis Franklin-listed configuration is the C25-B-A-R-BSP with a brass body, 25mm male and female BSPT connections and a dry-contact reed-switch electrical module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWhat the C25 does\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDetects whether water is flowing through the pipe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides a normally open electrical signal when flow is detected\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides an external flow signal for compatible no-flow protection equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCan help stop a pump following loss of flow when connected to the correct controller\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCan provide flow-status signalling to a relay, control panel or programmable logic controller\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDoes not independently switch or protect a pump without compatible control equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eCompatible pumps and applications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe C25 can be used with Franklin MH and EVR pumps and other clean-water pump systems where:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eThe pipe connection is 25mm or 1-inch BSPT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaximum flow does not exceed 100 litres per minute\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eA compatible flow-switch input, relay or control panel is installed\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe pump and pipework operate within the switch’s pressure and temperature limits\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIt can provide the external flow signal required by Franklin NFT no-flow protection when correctly connected to a compatible CP1 or CP3 full control panel.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSuitable applications include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePump no-flow protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePressure-boosting systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlow confirmation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eClean-water transfer systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTank-filling systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRelay and programmable-controller signalling\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAvailable model\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eC25-B-A-R-BSP – Kelco C25 inline flow switch with 25mm male and female BSPT connections and dry-contact reed-switch output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNo alternative C25 configuration is listed in the Franklin Electric Australia 2026 price list.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWhat is included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOne Kelco C25 inline flow switch\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBrass 25mm threaded flow-switch body\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFactory-fitted dry-contact electrical module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternal flow-sensing piston and retainer\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eNot included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFranklin NFT protection relay\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCP1 or CP3 control panel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrical cable or external relay\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePump or motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePipe unions, fittings or adaptors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCheck valve or inlet strainer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstallation or electrical connection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation and selection warning\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe C25-B dry-contact module is intended for control, relay, telemetry and programmable-controller signalling. It is rated to switch a maximum of 40 watts, 1 amp resistive and is not suitable for directly switching a pump motor or other inductive load.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe switch must be connected to a compatible relay, controller or control-panel input. All electrical connection must be completed by a licensed electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eMaximum recommended flow is 100 litres per minute. Do not use the C25 on larger Franklin pumps or pipework that can exceed this flow rate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe male threaded end is the inlet and the switch must be installed in the correct flow direction. It can be mounted horizontally or vertically.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe C25 is designed for clean liquids. Iron, iron scale, sediment and foreign material can interfere with the magnetic piston. Install a suitable upstream strainer where contamination may be present.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRapid flow reversal can damage the internal piston. A correctly selected non-return valve immediately upstream may be required. Pipe unions are also recommended so the switch can be removed for inspection and cleaning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConfirm pipe size, flow rate, liquid type, operating temperature, system pressure and controller compatibility before ordering.\u003c\/span\u003e\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"Default Title","offer_id":43623306428464,"sku":null,"price":289.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Kelco-C25-Inline-Flow-Switch.png?v=1789526401"},{"product_id":"kelco-f-h-25b-heavy-duty-paddle-flow-switch-25mm-bsp","title":"Kelco F-H-25B Heavy-Duty Paddle Flow Switch – 25mm BSP","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Australian-made Kelco F-H-25B is a heavy-duty paddle flow switch designed to detect liquid flow in 25mm and larger pipework.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIt uses an adjustable glass-fibre-reinforced polypropylene paddle and a seal-less magnetic mechanism to operate an internal single-pole double-throw switch. It can provide flow confirmation, no-flow protection or an automatic control signal to a compatible pump-control panel, relay or contactor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Franklin-listed F-H-25B has an all-polypropylene wetted section, 25mm male BSP threaded process connection, standard high-voltage control switch and built-in manual override.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWhat the flow switch does\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDetects flow or loss of flow inside the pipe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides normally open and normally closed control contacts\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCan provide an external signal for pump no-flow protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCan operate a pump starter, relay, contactor or timer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIncludes a manual override for commissioning and functional testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCan provide the external flow signal required by compatible Franklin NFT protection equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eCompatible pumps and applications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe F-H-25B can be used with Franklin MH, EVR and bore-pump systems when connected through correctly selected control equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSuitable applications include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePump no-flow and loss-of-prime protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePressure-boosting systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBore-water transfer systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTank filling and water-transfer systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIrrigation pipework\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHot and cold clean-water systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible Franklin CP1 and CP3 full control panels fitted with NFT protection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe paddle can be trimmed to suit pipe sizes from 25mm upward. The correct paddle length depends on the pipe diameter, flow rate, liquid and installation arrangement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAvailable model\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eF-H-25B – Standard Kelco F Series paddle flow switch with 25mm BSP polypropylene process connection, adjustable polypropylene paddle, manual override and high-voltage single-pole double-throw control switch\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNo stainless-steel or low-voltage F Series variants are included in this Franklin-listed product.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWhat is included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOne Kelco F-H-25B paddle flow switch\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFactory-fitted standard H electrical switch\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdjustable glass-fibre-reinforced polypropylene paddle\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e25mm male BSP polypropylene process connection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilt-in manual override\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eM20 cable gland\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eNot included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePipe tee, tapping saddle or flow-switch manifold\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFranklin NFT relay or pump control panel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrical cable, external relay or contactor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePump or motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstallation or electrical connection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplacement paddle\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation and selection warning\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe paddle must be correctly trimmed for the pipe diameter and expected flow rate. It must clear the inside of the pipe by at least 4mm. Incorrect trimming can prevent the switch from detecting flow or cause excessive restriction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAllow at least five pipe diameters of straight pipe before and after the switch. The switch must be square to the direction of flow, with the flow arrow pointing downstream. It must not be mounted underneath horizontal pipework. In vertical pipework, flow must travel upward.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe polypropylene model has a maximum pressure rating of 18 bar at ambient temperature. Its pressure rating must be reduced as temperature increases, reaching a maximum of only 1 bar absolute at 60°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlthough the standard H switch can directly control a 240-volt motor up to 375 watts or 0.5 horsepower, most Franklin pumps exceed this limit. Larger single-phase pumps and all three-phase pumps must be controlled through a correctly selected relay, contactor or control panel.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe manual override is provided for testing and commissioning. It must not be used to bypass required flow protection during normal operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConfirm the pipe diameter, minimum and maximum flow, liquid type, pressure, temperature, paddle length and controller compatibility before ordering. All electrical work must be completed by a licensed electrician.\u003c\/span\u003e\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"Yes","offer_id":43623354073136,"sku":null,"price":394.0,"currency_code":"AUD","in_stock":true},{"title":"No","offer_id":43623354105904,"sku":null,"price":359.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Kelco-F-H-25B-Paddle-Flow-Switch.png?v=1789526955"},{"product_id":"304-stainless-steel-bore-pump-flow-switch-manifold","title":"304 Stainless-Steel Bore Pump \u0026 Flow-Switch Manifold","description":"\u003cp\u003eThe 304 Stainless-Steel Bore Pump Manifold provides a strong, corrosion-resistant connection point for assembling the controls and plumbing used at the top of a bore or pressure-pump installation.\u003c\/p\u003e\n\u003cp\u003eEach manifold is manufactured from 304 stainless steel, measures 300mm long and is supplied with welded sockets for connecting compatible equipment. Available in a straight configuration or with an integrated 90-degree bend to suit different bore-head and discharge-pipe layouts.\u003c\/p\u003e\n\u003cp\u003eDepending on the completed system design, the manifold can provide connection points for a compatible flow switch, pressure gauge, pressure switch or pressure transducer, pressure tank, valves and associated pipework. The manifold itself does not detect flow, control the pump or provide dry-run protection.\u003c\/p\u003e\n\u003ch3\u003eSuitable pumps and applications\u003c\/h3\u003e\n\u003cp\u003eSuitable for Franklin FPS bore pumps and other compatible bore, tank and pressure-pump systems where the selected manifold diameter, pipe connections, operating pressure and component layout are suitable.\u003c\/p\u003e\n\u003cp\u003eTypical applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDomestic and rural bore-pump installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure systems supplied from a bore or tank\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePump systems using a Kelco C25 inline flow switch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystems using a Kelco F-H-25B paddle flow switch, subject to correct installation arrangements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBore heads requiring a central stainless-steel mounting point for pressure-system components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable variants\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eStraight manifold with welded sockets:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e25mm × 300mm straight manifold – 304 stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e32mm × 300mm straight manifold – 304 stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e40mm × 300mm straight manifold – 304 stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50mm × 300mm straight manifold – 304 stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eManifold with 90-degree bend and welded sockets:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e25mm × 300mm manifold with 90-degree bend – 304 stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e32mm × 300mm manifold with 90-degree bend – 304 stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e40mm × 300mm manifold with 90-degree bend – 304 stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50mm × 300mm manifold with 90-degree bend – 304 stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat is included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOne 300mm-long 304 stainless-steel manifold\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWelded connection sockets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStraight or 90-degree configuration, as selected\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat is not included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFlow switch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure switch or pressure transducer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure gauge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure tank\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCheck valves or isolation valves\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBore cap or bore head\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdaptors, unions or additional pipe fittings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThread-sealing materials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical controls or wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and selection warning\u003c\/h3\u003e\n\u003cp\u003eConfirm the required pipe diameter, socket sizes, thread arrangement, operating pressure and component layout before ordering. Franklin’s price list identifies the nominal manifold diameter and welded sockets but does not provide the complete socket-thread configuration.\u003c\/p\u003e\n\u003cp\u003eThe straight and 90-degree models should be selected according to the physical pipe layout and available installation space. The manifold must be properly supported so that the weight of valves, tanks and controls is not transferred to the bore cap or pump riser pipe.\u003c\/p\u003e\n\u003cp\u003eUse appropriate pressure-rated fittings and thread sealant. Any connected flow switch must be installed in the correct orientation and with the required pipe conditions specified by its manufacturer. Electrical switches and pump controls must be wired by a licensed electrician.\u003c\/p\u003e\n\u003cp\u003eThis manifold does not replace a check valve, pressure-control system, motor-protection device or dry-run protection system.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"25mm × 300mm straight","offer_id":43623994261552,"sku":null,"price":235.0,"currency_code":"AUD","in_stock":true},{"title":"32mm × 300mm straight","offer_id":43623994294320,"sku":null,"price":285.0,"currency_code":"AUD","in_stock":true},{"title":"40mm × 300mm straight","offer_id":43623994327088,"sku":null,"price":290.0,"currency_code":"AUD","in_stock":true},{"title":"50mm × 300mm straight","offer_id":43623994359856,"sku":null,"price":295.0,"currency_code":"AUD","in_stock":true},{"title":"25mm × 300mm with 90-degree bend","offer_id":43623994392624,"sku":null,"price":235.0,"currency_code":"AUD","in_stock":true},{"title":"32mm × 300mm with 90-degree bend","offer_id":43623994425392,"sku":null,"price":250.0,"currency_code":"AUD","in_stock":true},{"title":"40mm × 300mm with 90-degree bend","offer_id":43623994458160,"sku":null,"price":275.0,"currency_code":"AUD","in_stock":true},{"title":"50mm × 300mm with 90-degree bend","offer_id":43623994490928,"sku":null,"price":285.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Franklin-Compatible-304SS-Flow-Switch-Manifold.jpg?v=1789530519"},{"product_id":"3-core-and-earth-rubber-submersible-bore-pump-electrical-cable","title":"3-Core-and-Earth Rubber Submersible Bore Pump Electrical Cable","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHeavy-duty 3-core-and-earth rubber electrical cable suitable for connecting compatible submersible bore-pump motors to their surface starter, controller or electrical supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe flexible rubber outer sheath helps protect the internal conductors in wet, outdoor and demanding bore-pump installations. Cable is supplied in cut lengths, allowing the conductor size and length to be selected for the individual pump installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis is a third-party compatible installation accessory and is not manufactured or branded by Franklin Electric.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCompatible pumps and applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSuitable for correctly matched:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFranklin FPS 240V three-wire single-phase bore-pump motors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFranklin FPS 415V three-phase bore-pump motors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible three-wire single-phase and three-phase submersible motors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBore, irrigation, stock-water and rural pumping installations\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eAvailable cable sizes\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e4mm² 3-core-and-earth rubber cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e6mm² 3-core-and-earth rubber cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e10mm² 3-core-and-earth rubber cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e16mm² 3-core-and-earth rubber cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAvailable in 10-metre increments from 10 metres through to 200 metres.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSelected length of 3-core-and-earth rubber electrical cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is not included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBore pump or motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStarter box, control panel or motor protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWaterproof cable splice kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCable joining or termination service\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrical installation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStainless-steel safety cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCable ties or installation hardware\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eInstallation and selection warning\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe cable size must be confirmed by a licensed electrician using the motor voltage, phase, rated current, starting current, total cable length, supply conditions and permitted voltage drop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDo not select cable size from bore depth alone. Undersized cable can cause excessive voltage drop, starting problems, nuisance tripping, overheating and permanent motor damage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConfirm that the cable construction and submersion rating are suitable for the complete installation. Any submerged connection must be completed using a correctly sized waterproof splice kit. All electrical installation, connection and testing must be completed by a licensed electrician in accordance with applicable Australian requirements.\u003c\/span\u003e\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"4mm \/ 10m","offer_id":43624267120688,"sku":null,"price":100.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 20m","offer_id":43624267153456,"sku":null,"price":200.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 30m","offer_id":43624267186224,"sku":null,"price":300.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 40m","offer_id":43624267218992,"sku":null,"price":400.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 50m","offer_id":43624267251760,"sku":null,"price":500.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 60m","offer_id":43624267284528,"sku":null,"price":600.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 70m","offer_id":43624267317296,"sku":null,"price":700.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 80m","offer_id":43624267350064,"sku":null,"price":800.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 90m","offer_id":43624267382832,"sku":null,"price":900.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 100m","offer_id":43624267415600,"sku":null,"price":1000.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 110m","offer_id":43624267448368,"sku":null,"price":1100.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 120m","offer_id":43624267481136,"sku":null,"price":1200.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 130m","offer_id":43624267513904,"sku":null,"price":1300.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 140m","offer_id":43624267546672,"sku":null,"price":1400.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 150m","offer_id":43624267579440,"sku":null,"price":1500.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 160m","offer_id":43624267612208,"sku":null,"price":1600.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 170m","offer_id":43624267644976,"sku":null,"price":1700.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 180m","offer_id":43624267677744,"sku":null,"price":1800.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 190m","offer_id":43624267710512,"sku":null,"price":1900.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 200m","offer_id":43624267743280,"sku":null,"price":2000.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 10m","offer_id":43624267776048,"sku":null,"price":135.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 20m","offer_id":43624267808816,"sku":null,"price":270.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 30m","offer_id":43624267841584,"sku":null,"price":405.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 40m","offer_id":43624267874352,"sku":null,"price":540.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 50m","offer_id":43624267907120,"sku":null,"price":675.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 60m","offer_id":43624267939888,"sku":null,"price":810.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 70m","offer_id":43624267972656,"sku":null,"price":945.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 80m","offer_id":43624268005424,"sku":null,"price":1080.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 90m","offer_id":43624268038192,"sku":null,"price":1215.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 100m","offer_id":43624268070960,"sku":null,"price":1350.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 110m","offer_id":43624268103728,"sku":null,"price":1485.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 120m","offer_id":43624268136496,"sku":null,"price":1620.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 130m","offer_id":43624268169264,"sku":null,"price":1755.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 140m","offer_id":43624268202032,"sku":null,"price":1890.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 150m","offer_id":43624268234800,"sku":null,"price":2025.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 160m","offer_id":43624268267568,"sku":null,"price":2160.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 170m","offer_id":43624268300336,"sku":null,"price":2295.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 180m","offer_id":43624268333104,"sku":null,"price":2430.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 190m","offer_id":43624268365872,"sku":null,"price":2565.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 200m","offer_id":43624268398640,"sku":null,"price":2700.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 10m","offer_id":43624268431408,"sku":null,"price":240.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 20m","offer_id":43624268464176,"sku":null,"price":480.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 30m","offer_id":43624268496944,"sku":null,"price":720.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 40m","offer_id":43624268529712,"sku":null,"price":960.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 50m","offer_id":43624268562480,"sku":null,"price":1200.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 60m","offer_id":43624268595248,"sku":null,"price":1440.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 70m","offer_id":43624268628016,"sku":null,"price":1680.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 80m","offer_id":43624268660784,"sku":null,"price":1920.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 90m","offer_id":43624268693552,"sku":null,"price":2160.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 100m","offer_id":43624268726320,"sku":null,"price":2400.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 110m","offer_id":43624268759088,"sku":null,"price":2640.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 120m","offer_id":43624268791856,"sku":null,"price":2880.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 130m","offer_id":43624268824624,"sku":null,"price":3120.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 140m","offer_id":43624268857392,"sku":null,"price":3360.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 150m","offer_id":43624268890160,"sku":null,"price":3600.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 160m","offer_id":43624268922928,"sku":null,"price":3840.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 170m","offer_id":43624268955696,"sku":null,"price":4080.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 180m","offer_id":43624268988464,"sku":null,"price":4320.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 190m","offer_id":43624269021232,"sku":null,"price":4560.0,"currency_code":"AUD","in_stock":true},{"title":"10mm \/ 200m","offer_id":43624269054000,"sku":null,"price":4800.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 10m","offer_id":43624269086768,"sku":null,"price":353.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 20m","offer_id":43624269119536,"sku":null,"price":706.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 30m","offer_id":43624269152304,"sku":null,"price":1059.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 40m","offer_id":43624269185072,"sku":null,"price":1412.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 50m","offer_id":43624269217840,"sku":null,"price":1765.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 60m","offer_id":43624269250608,"sku":null,"price":2118.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 70m","offer_id":43624269283376,"sku":null,"price":2471.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 80m","offer_id":43624269316144,"sku":null,"price":2824.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 90m","offer_id":43624269348912,"sku":null,"price":3177.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 100m","offer_id":43624269381680,"sku":null,"price":3530.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 110m","offer_id":43624269414448,"sku":null,"price":3883.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 120m","offer_id":43624269447216,"sku":null,"price":4236.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 130m","offer_id":43624269479984,"sku":null,"price":4589.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 140m","offer_id":43624269512752,"sku":null,"price":4942.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 150m","offer_id":43624269545520,"sku":null,"price":5296.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 160m","offer_id":43624269578288,"sku":null,"price":5648.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 170m","offer_id":43624269611056,"sku":null,"price":6001.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 180m","offer_id":43624269643824,"sku":null,"price":6354.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 190m","offer_id":43624269676592,"sku":null,"price":6707.0,"currency_code":"AUD","in_stock":true},{"title":"16mm \/ 200m","offer_id":43624269709360,"sku":null,"price":7060.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/30cdb967-7080-4f20-8d37-61f741b9dada.png?v=1789533082"},{"product_id":"316-stainless-steel-bore-pump-safety-cable-with-clamps","title":"316 Stainless-Steel Bore Pump Safety Cable with Clamps","description":"\u003cp\u003e316 Stainless-Steel Bore Pump Safety Cable provides a secondary means of retrieving a submersible bore pump if the riser pipe or pump connection fails.\u003c\/p\u003e\n\u003cp\u003eManufactured from corrosion-resistant 316 stainless steel, the cable is suitable for permanent bore-pump installations and is available in three diameters to accommodate different pump weights and installation depths.\u003c\/p\u003e\n\u003cp\u003eMatching stainless-steel cable clamps are included with the selected cable length.\u003c\/p\u003e\n\u003ch3\u003eCompatible pumps and applications\u003c\/h3\u003e\n\u003cp\u003eSuitable for correctly selected:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFranklin FPS submersible bore pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFranklin solar submersible bore pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOther compatible submersible bore-pump installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDomestic, agricultural, irrigation and stock-water bores\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallations using poly riser pipe or other suitable bore-pump discharge systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable cable sizes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e4mm diameter 316 stainless-steel safety cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e5mm diameter 316 stainless-steel safety cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e6mm diameter 316 stainless-steel safety cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable lengths:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e10 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e20 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e30 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e40 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e60 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e70 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e80 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e90 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e100 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e110 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e120 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e130 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e140 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e150 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e160 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e170 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e180 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e190 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e200 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat is included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSelected length of 316 stainless-steel safety cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMatching stainless-steel cable clamps required for the selected cable option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat is not included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBore pump or motor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBore cap or bore head\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRiser pipe or flexible bore hose\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical drop cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable ties\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdditional thimbles, shackles or mounting hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and selection warning\u003c\/h3\u003e\n\u003cp\u003eThe correct cable diameter must be selected according to the complete suspended pump assembly, installation depth, cable length, fastening method and expected retrieval load.\u003c\/p\u003e\n\u003cp\u003eThe safety cable is a secondary retrieval system and should not normally carry the operating weight of the pump. The pump must be properly supported by its correctly selected riser pipe or engineered flexible riser system.\u003c\/p\u003e\n\u003cp\u003eSecure the safety cable to an independent, suitably rated bore-head attachment point. Use the correct size, number and orientation of cable clamps. Incorrectly installed clamps or an undersized cable may fail when the pump is retrieved.\u003c\/p\u003e\n\u003cp\u003eDo not attach the safety cable to electrical cable, lightweight cable ties or unsupported bore-cap components. Installation should be completed or checked by an experienced bore-pump installer.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"4mm \/ 10m","offer_id":43624350810160,"sku":null,"price":33.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 20m","offer_id":43624350842928,"sku":null,"price":66.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 30m","offer_id":43624350875696,"sku":null,"price":99.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 40m","offer_id":43624350908464,"sku":null,"price":132.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 50m","offer_id":43624350941232,"sku":null,"price":165.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 60m","offer_id":43624350974000,"sku":null,"price":198.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 70m","offer_id":43624351006768,"sku":null,"price":231.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 80m","offer_id":43624351039536,"sku":null,"price":264.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 90m","offer_id":43624351072304,"sku":null,"price":297.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 100m","offer_id":43624351105072,"sku":null,"price":330.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 110m","offer_id":43624351137840,"sku":null,"price":363.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 120m","offer_id":43624351170608,"sku":null,"price":396.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 130m","offer_id":43624351203376,"sku":null,"price":429.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 140m","offer_id":43624351236144,"sku":null,"price":462.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 150m","offer_id":43624351268912,"sku":null,"price":495.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 160m","offer_id":43624351301680,"sku":null,"price":528.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 170m","offer_id":43624351334448,"sku":null,"price":561.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 180m","offer_id":43624351367216,"sku":null,"price":594.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 190m","offer_id":43624351399984,"sku":null,"price":627.0,"currency_code":"AUD","in_stock":true},{"title":"4mm \/ 200m","offer_id":43624351432752,"sku":null,"price":660.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 10m","offer_id":43624351465520,"sku":null,"price":44.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 20m","offer_id":43624351498288,"sku":null,"price":88.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 30m","offer_id":43624351531056,"sku":null,"price":132.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 40m","offer_id":43624351563824,"sku":null,"price":176.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 50m","offer_id":43624351596592,"sku":null,"price":220.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 60m","offer_id":43624351629360,"sku":null,"price":264.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 70m","offer_id":43624351662128,"sku":null,"price":308.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 80m","offer_id":43624351694896,"sku":null,"price":352.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 90m","offer_id":43624351727664,"sku":null,"price":396.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 100m","offer_id":43624351760432,"sku":null,"price":440.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 110m","offer_id":43624351793200,"sku":null,"price":484.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 120m","offer_id":43624351825968,"sku":null,"price":528.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 130m","offer_id":43624351858736,"sku":null,"price":572.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 140m","offer_id":43624351891504,"sku":null,"price":616.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 150m","offer_id":43624351924272,"sku":null,"price":660.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 160m","offer_id":43624351957040,"sku":null,"price":704.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 170m","offer_id":43624351989808,"sku":null,"price":748.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 180m","offer_id":43624352022576,"sku":null,"price":792.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 190m","offer_id":43624352055344,"sku":null,"price":836.0,"currency_code":"AUD","in_stock":true},{"title":"5mm \/ 200m","offer_id":43624352088112,"sku":null,"price":880.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 10m","offer_id":43624352120880,"sku":null,"price":64.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 20m","offer_id":43624352153648,"sku":null,"price":128.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 30m","offer_id":43624352186416,"sku":null,"price":192.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 40m","offer_id":43624352219184,"sku":null,"price":256.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 50m","offer_id":43624352251952,"sku":null,"price":320.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 60m","offer_id":43624352284720,"sku":null,"price":384.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 70m","offer_id":43624352317488,"sku":null,"price":448.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 80m","offer_id":43624352350256,"sku":null,"price":512.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 90m","offer_id":43624352383024,"sku":null,"price":576.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 100m","offer_id":43624352415792,"sku":null,"price":640.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 110m","offer_id":43624352448560,"sku":null,"price":704.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 120m","offer_id":43624352481328,"sku":null,"price":768.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 130m","offer_id":43624352514096,"sku":null,"price":832.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 140m","offer_id":43624352546864,"sku":null,"price":896.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 150m","offer_id":43624352579632,"sku":null,"price":960.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 160m","offer_id":43624352612400,"sku":null,"price":1024.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 170m","offer_id":43624352645168,"sku":null,"price":1088.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 180m","offer_id":43624352677936,"sku":null,"price":1152.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 190m","offer_id":43624352710704,"sku":null,"price":1216.0,"currency_code":"AUD","in_stock":true},{"title":"6mm \/ 200m","offer_id":43624352743472,"sku":null,"price":1280.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/e84de141-bcdd-4165-8ceb-9294afd5bbda.png?v=1789534796"},{"product_id":"franklin-6-inch-submersible-pump-waterproof-cable-splice-kit","title":"Franklin 6-Inch Submersible Pump Waterproof Cable Splice Kit","description":"\u003cp\u003eThe Franklin 6-Inch Submersible Pump Waterproof Cable Splice Kit provides the components needed to create a sealed electrical connection between a compatible 6-inch submersible motor lead and the electrical drop cable running up the bore.\u003c\/p\u003e\n\u003cp\u003eDesigned for permanently submerged bore-pump installations, the kit uses crimp connectors, resin-filled heat-shrink tubes, mastic tape and an outer heat-shrink sleeve to protect the completed electrical joint against water ingress.\u003c\/p\u003e\n\u003ch3\u003eSuitable Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible Franklin 6-inch submersible motors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBore and well pump installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDirect-on-line motor wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStar-delta motor wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJoining a compatible submersible motor lead to electrical drop cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe term “6-inch” refers to the motor and installation category. It does not mean the kit will suit every cable size used with every 6-inch motor.\u003c\/p\u003e\n\u003ch3\u003eAvailable Pack Sizes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSingle 6-Inch Splice Kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBox of Five 6-Inch Splice Kits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBox of Ten 6-Inch Splice Kits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEach Kit Includes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFour 4 mm crimp connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFour 12 mm × 50 mm resin-filled heat-shrink connector tubes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne 30 mm × 400 mm resin-filled outer heat-shrink tube\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBlack mastic sealing tape\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCleaning wipe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAluminium-oxide abrasive paper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNot Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSubmersible electrical drop cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePump or motor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCrimping tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeat gun\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical testing equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation labour\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Selection Warning\u003c\/h3\u003e\n\u003cp\u003eConfirm the motor wiring arrangement, number of conductors and actual conductor size of both cables before ordering. The supplied 4 mm crimp connectors will not suit every drop-cable size used with a 6-inch motor. Larger conductors may require a different approved cable-jointing kit or connection method.\u003c\/p\u003e\n\u003cp\u003eThis kit creates a permanently submerged electrical joint and must be installed by a suitably qualified electrician. The joint must be correctly crimped, sealed and tested for insulation resistance, continuity and earthing before the pump is lowered into the bore.\u003c\/p\u003e\n\u003cp\u003eIncorrect selection or installation can allow water into the cable joint, causing electrical failure, electric shock or permanent motor damage. Each kit is intended for one installation only.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"One Termination Kit","offer_id":43624401174576,"sku":null,"price":45.0,"currency_code":"AUD","in_stock":true},{"title":"5 Termination Kits","offer_id":43624401207344,"sku":null,"price":199.0,"currency_code":"AUD","in_stock":true},{"title":"10 Termination Kits","offer_id":43624401240112,"sku":null,"price":389.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/54e49c7c-43c6-4907-83e6-ced491b0c359.png?v=1789536428"},{"product_id":"bore-pump-caps-coated-mild-steel-304-stainless-steel-with-lugs","title":"Bore Pump Caps – Coated Mild Steel \u0026 304 Stainless Steel with Lugs","description":"\u003cp\u003eThese bore pump caps provide a strong cover over the top of a water bore while allowing the pump’s rising main and electrical cable to exit the bore casing.\u003c\/p\u003e\n\u003cp\u003eChoose between economical coated mild-steel construction or corrosion-resistant 304 stainless steel with integrated attachment lugs for a compatible safety cable.\u003c\/p\u003e\n\u003ch3\u003eMaterial Options\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCoated mild-steel bore caps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA practical and economical option for standard bore-pump installations. These caps have a female BSP rising-main connection but do not include safety-cable attachment lugs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e304 stainless-steel bore caps with lugs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide greater corrosion resistance for exposed outdoor and water-bore environments. These variants include integrated attachment lugs for connecting a correctly selected stainless steel safety cable.\u003c\/p\u003e\n\u003ch3\u003eAvailable Variants\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e32mm (1¼-inch) BSP Female Coated Mild-Steel Bore Cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e40mm (1½-inch) BSP Female Coated Mild-Steel Bore Cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50mm (2-inch) BSP Female Coated Mild-Steel Bore Cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e32mm (1¼-inch) 304 Stainless-Steel Bore Cap with Lugs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e40mm (1½-inch) 304 Stainless-Steel Bore Cap with Lugs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50mm (2-inch) 304 Stainless-Steel Bore Cap with Lugs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe connection measurement refers to the rising-main connection size—not the bore-casing diameter.\u003c\/p\u003e\n\u003ch3\u003eWhat the Bore Cap Does\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCovers and helps protect the top of the bore casing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides a connection point for the pump’s rising main\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides an exit point for the electrical drop cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHelps keep the rising main and electrical cable organised\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStainless-steel variants provide attachment lugs for a safety cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSuitable Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFranklin FPS 4-inch bore-pump installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFranklin Solar SUB DC bore-pump installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOther compatible submersible bore pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommon 4-inch to 6-inch bore-casing installations, subject to confirming actual dimensions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystems using 32mm, 40mm or 50mm rising main\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatibility depends on the bore-casing dimensions, rising-main connection, electrical-cable entry and complete installation design.\u003c\/p\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOne selected bore cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated attachment lugs on the 304 stainless-steel variants only\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNot Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eStainless steel safety cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety-cable grips or clamps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRising main or discharge pipe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical drop cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable gland or sealing components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePump or motor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation labour\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Selection Warning\u003c\/h3\u003e\n\u003cp\u003eConfirm the bore casing’s inside and outside diameter, bore-cap dimensions, rising-main size, thread arrangement, electrical-cable entry and required sealing method before ordering. Do not select the cap from the pump’s discharge size alone.\u003c\/p\u003e\n\u003cp\u003eThe coated mild-steel variants do not include safety-cable attachment lugs. A separate approved safety-cable anchoring method will be required where a safety cable is used.\u003c\/p\u003e\n\u003cp\u003eThe Franklin price list does not provide a load rating for the stainless-steel attachment lugs. Do not assume the lugs can carry the entire suspended weight of the pump, motor, rising main, water column and electrical cable without confirmation from the supplier or installer.\u003c\/p\u003e\n\u003cp\u003eThe safety cable, grips and attachment method must be correctly selected for the total suspended load. Installation should be completed by an experienced bore-pump installer, and all openings should be properly sealed to help prevent contamination entering the bore.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"32mm Coated Mild Steel","offer_id":43624478474288,"sku":null,"price":85.0,"currency_code":"AUD","in_stock":true},{"title":"40mm Coated Mild Steel","offer_id":43624478507056,"sku":null,"price":95.0,"currency_code":"AUD","in_stock":true},{"title":"50mm Coated Mild Steel","offer_id":43624478539824,"sku":null,"price":100.0,"currency_code":"AUD","in_stock":true},{"title":"32mm 304 Stainless Steel with Lugs","offer_id":43624478572592,"sku":null,"price":289.0,"currency_code":"AUD","in_stock":true},{"title":"40mm 304 Stainless Steel with Lugs","offer_id":43624478605360,"sku":null,"price":289.0,"currency_code":"AUD","in_stock":true},{"title":"50mm 304 Stainless Steel with Lugs","offer_id":43624478638128,"sku":null,"price":209.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/akms40501_700x700_png.webp?v=1789538038"},{"product_id":"aip-brass-spring-check-valve-bsp-non-return-valve","title":"AIP Brass Spring Check Valve – BSP Non-Return Valve","description":"\u003cp dir=\"auto\"\u003eThe AIP Brass Spring Check Valve is a threaded non-return valve designed to allow flow in one direction while helping prevent reverse flow through connected pipework.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIt can be selected for suitable pump discharge lines, tank systems, irrigation pipework and general water-transfer applications. This is a \u003cstrong\u003ethird-party AIP accessory\u003c\/strong\u003e that may be used with Franklin pump installations when the valve size, thread connection and application are suitable. It is not manufactured by Franklin Electric or supplied with a Franklin pump.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eWhat the Product Does\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHelps prevent water flowing backwards through the pipework\u003c\/li\u003e\n\u003cli\u003eUses an internal spring-operated closing mechanism\u003c\/li\u003e\n\u003cli\u003eConnects directly into compatible BSP threaded pipework\u003c\/li\u003e\n\u003cli\u003eProvides a compact non-return valve option for pump installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eCompatible Pumps and Applications\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003ePotentially suitable for pipework connected to Franklin ADJ, MH, EVR, CPS75, FPS and Solar SUB DC pump installations, depending on the required connection size and system design.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eCompatibility must be confirmed from the pump connection, pipe size and installation requirements. The valve is not confirmed as a direct-fit accessory for every Franklin pump.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne AIP brass spring check valve in the selected size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eWhat Is Not Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThread adaptors or reducers\u003c\/li\u003e\n\u003cli\u003ePipe fittings\u003c\/li\u003e\n\u003cli\u003eThread-sealing tape or compound\u003c\/li\u003e\n\u003cli\u003eInstallation labour\u003c\/li\u003e\n\u003cli\u003ePump or control equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eInstallation and Selection Warning\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eConfirm the required valve size, thread type, flow direction and suitability for the pumped liquid before ordering. The supplied AIP price list does not confirm WaterMark approval, pressure rating, temperature rating or permitted installation orientation. Do not use the valve where a particular approval or operating rating is required unless that information has been independently confirmed.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"1\/4 Inch BSP","offer_id":43624634679344,"sku":null,"price":35.95,"currency_code":"AUD","in_stock":true},{"title":"3\/8 Inch BSP","offer_id":43624634712112,"sku":null,"price":11.95,"currency_code":"AUD","in_stock":true},{"title":"1\/2 Inch BSP","offer_id":43624634744880,"sku":null,"price":10.95,"currency_code":"AUD","in_stock":true},{"title":"3\/4 Inch BSP","offer_id":43624634777648,"sku":null,"price":15.95,"currency_code":"AUD","in_stock":true},{"title":"1 Inch BSP","offer_id":43624634810416,"sku":null,"price":21.95,"currency_code":"AUD","in_stock":true},{"title":"1 1\/4 Inch BSP","offer_id":43624634843184,"sku":null,"price":33.95,"currency_code":"AUD","in_stock":true},{"title":"1 1\/2 Inch BSP","offer_id":43624634875952,"sku":null,"price":45.95,"currency_code":"AUD","in_stock":true},{"title":"2 Inch BSP","offer_id":43624634908720,"sku":null,"price":63.95,"currency_code":"AUD","in_stock":true},{"title":"2 1\/2 Inch BSP","offer_id":43624634941488,"sku":null,"price":140.95,"currency_code":"AUD","in_stock":true},{"title":"3 Inch BSP","offer_id":43624634974256,"sku":null,"price":177.95,"currency_code":"AUD","in_stock":true},{"title":"4 Inch BSP","offer_id":43624635007024,"sku":null,"price":266.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/images_fe54b907-f02a-49b3-bbdb-de53220784af.jpg?v=1789540918"},{"product_id":"philmac-full-flow-non-return-valve-female-bsp","title":"Philmac Full-Flow Non-Return Valve – Female BSP","description":"\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Australian-made Philmac Full-Flow Non-Return Valve is designed to allow water to travel in one direction while preventing backflow and unwanted pipeline drainage.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eManufactured from lightweight thermoplastic materials with a corrosion-resistant stainless-steel spring, it is suitable for pump discharge pipework, irrigation, stock-water systems, tank transfer systems and general water-transfer applications.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe female BSP threaded connections allow the valve to connect to compatible male BSP pipe fittings. Its improved internal flow path helps reduce turbulence while providing reliable low-pressure sealing.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis is a \u003cstrong\u003egenuine Philmac product\u003c\/strong\u003e. It is not manufactured by Franklin Electric, but it can be used in correctly designed pipework connected to Franklin pumps.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eWhat the Product Does\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrevents reverse water flow\u003c\/li\u003e\n\u003cli\u003eHelps stop pipelines from draining\u003c\/li\u003e\n\u003cli\u003eHelps maintain pump prime in suitable systems\u003c\/li\u003e\n\u003cli\u003eProtects pumps and connected equipment from backflow\u003c\/li\u003e\n\u003cli\u003eIndicates the required flow direction on the valve body\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eCompatible Pumps and Applications\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eSuitable for correctly sized pipework connected to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin ADJ pressure and jet pumps\u003c\/li\u003e\n\u003cli\u003eFranklin MH, EVR and CPS75 multistage pumps\u003c\/li\u003e\n\u003cli\u003eFranklin FPS bore pumps\u003c\/li\u003e\n\u003cli\u003eFranklin Solar SUB DC installations\u003c\/li\u003e\n\u003cli\u003eIrrigation and stock-water systems\u003c\/li\u003e\n\u003cli\u003eTank filling and water-transfer systems\u003c\/li\u003e\n\u003cli\u003eGravity-fed water systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne genuine Philmac full-flow non-return valve in the selected size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eWhat Is Not Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMale BSP adaptors or pipe fittings\u003c\/li\u003e\n\u003cli\u003eThread tape or sealing compound\u003c\/li\u003e\n\u003cli\u003eFoot-valve filter\u003c\/li\u003e\n\u003cli\u003ePump, pipework or installation\u003c\/li\u003e\n\u003cli\u003eReplacement internal components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eInstallation and Selection Warning\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eSelect the valve according to the actual BSP pipe connection, required flow and system pressure. Install it with the flow-direction arrow pointing downstream. Confirm whether the pump already contains a non-return valve and whether an additional valve is appropriate for the system. Incorrect sizing or placement can restrict flow or contribute to water hammer. Installation should follow Philmac’s current instructions.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"20mm (3\/4 Inch) Female BSP","offer_id":43624702083120,"sku":null,"price":39.95,"currency_code":"AUD","in_stock":true},{"title":"25mm (1 Inch) Female BSP","offer_id":43624702115888,"sku":null,"price":46.95,"currency_code":"AUD","in_stock":true},{"title":"32mm (1 1\/4 Inch) Female BSP","offer_id":43624702148656,"sku":null,"price":61.95,"currency_code":"AUD","in_stock":true},{"title":"40mm (1 1\/2 Inch) Female BSP","offer_id":43624702181424,"sku":null,"price":69.95,"currency_code":"AUD","in_stock":true},{"title":"50mm (2 Inch) Female BSP","offer_id":43624702214192,"sku":null,"price":89.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Poly-Valve-Non-Return_62a1f014c5fc1_62a1f0168e1c2-1.jpg?v=1789542253"},{"product_id":"philmac-full-flow-foot-valve-with-strainer-female-bsp","title":"Philmac Full-Flow Foot Valve with Strainer – Female BSP","description":"\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Australian-made Philmac Full-Flow Foot Valve is installed at the submerged end of a pump suction line. It allows water to flow towards the pump while helping prevent the suction pipe from draining when the pump stops.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eAn integrated strainer helps prevent larger debris from entering the suction line. The lightweight thermoplastic construction provides impact, UV and corrosion resistance for rural, irrigation, stock-water and general water-transfer systems.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis is a \u003cstrong\u003egenuine Philmac product\u003c\/strong\u003e. It is not manufactured by Franklin Electric but can be used with compatible Franklin surface-pump installations.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eWhat the Product Does\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHelps maintain water in the suction line and pump prime\u003c\/li\u003e\n\u003cli\u003ePrevents reverse flow when the pump stops\u003c\/li\u003e\n\u003cli\u003eHelps prevent larger debris entering the suction pipe\u003c\/li\u003e\n\u003cli\u003eProvides a female BSP threaded suction-line connection\u003c\/li\u003e\n\u003cli\u003eCan be converted into a non-return valve by removing the filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eCompatible Pumps and Applications\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eBest suited to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFranklin ADJ self-priming jet pumps\u003c\/li\u003e\n\u003cli\u003eCompatible surface transfer and centrifugal pumps\u003c\/li\u003e\n\u003cli\u003eTank, dam and creek water transfer\u003c\/li\u003e\n\u003cli\u003eIrrigation and stock-water systems\u003c\/li\u003e\n\u003cli\u003eSuction-lift pumping installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eIt may only be used with Franklin MH, EVR or CPS75 pumps where the suction system is correctly designed and the pump remains properly flooded or primed. A foot valve does not make a non-self-priming pump self-priming.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eNot intended for Franklin FPS or Solar SUB DC submersible bore pumps.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne genuine Philmac full-flow foot valve\u003c\/li\u003e\n\u003cli\u003eMatching fitted inlet strainer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eWhat Is Not Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSuction hose or pipe\u003c\/li\u003e\n\u003cli\u003eMale BSP adaptors\u003c\/li\u003e\n\u003cli\u003eThread tape or sealing compound\u003c\/li\u003e\n\u003cli\u003ePump, priming equipment or installation\u003c\/li\u003e\n\u003cli\u003eFloat rig kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eInstallation and Selection Warning\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eInstall the foot valve at the lower end of the suction line, fully submerged and in the correct flow direction. Match the valve to the pump inlet and suction-pipe size. The suction line must remain airtight, adequately supported and correctly sized. An undersized valve or leaking suction connection can restrict pump performance or prevent the pump from priming. Follow Philmac’s current installation instructions.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"20mm (3\/4 Inch) Female BSP","offer_id":43624744779824,"sku":null,"price":42.95,"currency_code":"AUD","in_stock":true},{"title":"25mm (1 Inch) Female BSP","offer_id":43624744812592,"sku":null,"price":48.95,"currency_code":"AUD","in_stock":true},{"title":"32mm (1 1\/4 Inch) Female BSP","offer_id":43624744845360,"sku":null,"price":62.95,"currency_code":"AUD","in_stock":true},{"title":"40mm (1 1\/2 Inch) Female BSP","offer_id":43624744878128,"sku":null,"price":77.95,"currency_code":"AUD","in_stock":true},{"title":"50mm (2 Inch) Female BSP","offer_id":43624744910896,"sku":null,"price":98.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/Foot-Valve-95601600-HR-01-small-1200x800-1.jpg?v=1789542382"},{"product_id":"63mm-liquid-filled-pressure-gauge","title":"63mm Liquid-Filled Pressure Gauge","description":"\u003cp\u003eThe Franklin 63mm Liquid-Filled Pressure Gauge provides a clear indication of pump or system discharge pressure. It is suitable for monitoring bore pump, pressure pump and water-transfer installations and can help identify pressure-related problems when investigating reduced or interrupted water flow.\u003c\/p\u003e\n\u003cp\u003eAvailable in several pressure ranges to suit different pumping systems, including a rear-entry 0–1000 kPa option.\u003c\/p\u003e\n\u003ch3\u003eWhat is included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOne 63mm liquid-filled pressure gauge in the selected pressure range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat is not included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePlumbing manifold\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdaptors or reducers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThread-sealing materials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eSuitable for Franklin bore pumps, pressure pumps and other water-pump systems fitted with an appropriate pressure-gauge connection.\u003c\/p\u003e\n\u003ch3\u003eImportant selection and installation warning\u003c\/h3\u003e\n\u003cp\u003eSelect a gauge range that comfortably covers the system’s normal operating pressure and maximum possible pressure, including pressure surges. Confirm the required connection and entry position before ordering, as the Franklin price list does not specify the connection thread. The system must be completely depressurised before installation or servicing.\u003c\/p\u003e\n\u003cp\u003eThis is a genuine Franklin Electric supplied accessory.\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"63mm Liquid-Filled Pressure Gauge – 0–100 kPa","offer_id":43624843280432,"sku":null,"price":55.0,"currency_code":"AUD","in_stock":true},{"title":"63mm Liquid-Filled Pressure Gauge – 0–800 kPa","offer_id":43624843313200,"sku":null,"price":55.0,"currency_code":"AUD","in_stock":true},{"title":"63mm Liquid-Filled Pressure Gauge – 0–1000 kPa","offer_id":43624843345968,"sku":null,"price":55.0,"currency_code":"AUD","in_stock":true},{"title":"63mm Liquid-Filled Pressure Gauge – 0–1600 kPa","offer_id":43624843378736,"sku":null,"price":55.0,"currency_code":"AUD","in_stock":true},{"title":"63mm Liquid-Filled Pressure Gauge – 0–2500 kPa","offer_id":43624843411504,"sku":null,"price":55.0,"currency_code":"AUD","in_stock":true},{"title":"63mm Liquid-Filled Pressure Gauge – 0–1000 kPa Rear Entry","offer_id":43624843444272,"sku":null,"price":55.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/MZDW96AgL0hvAiHELP7noCDZ3SSuqwBxju48N3dObTKjVlTvHAFBjGvMPKeyxNAkLyXS4yZVikC-jyc0zd0zxgpBv1Z0lIlC2Z04SkTYoDX0B-YW7KhEa9HQILGKFaVFGKuWWlPGQ9UzBYK71XQlwptuzAG_889PMnFsDgQBexZULE3QTpEPM7X.jpg?v=1789543696"},{"product_id":"pressure-tanks","title":"Pressure Tanks","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFranklin Pressure Tanks store water under pressure and provide a small supply of water before the pump needs to restart. This helps reduce frequent pump cycling, supports smoother system operation and can extend pump and motor life.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAvailable in multiple tank sizes, pressure ratings and mounting configurations to suit compatible bore pumps, household pressure pumps, irrigation systems and water-transfer installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOne Franklin pressure tank in the selected size and configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is not included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePressure switch or controller\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePressure gauge\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManifold or connecting fittings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIsolation valves\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eImportant selection and installation warning\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe tank capacity, maximum pressure rating, connection size and mounting configuration must suit the pump and plumbing system. Confirm the correct tank selection before ordering. The tank must be correctly installed, supported and commissioned by a suitably qualified person.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese are genuine Franklin Electric supplied pressure tanks.\u003c\/span\u003e\u003c\/p\u003e","brand":"The Pump Shed Australia","offers":[{"title":"2L – 10 Bar Vertical Pipe Mounted – 1″ – 0.6L Draw","offer_id":43625049948208,"sku":null,"price":69.0,"currency_code":"AUD","in_stock":true},{"title":"8L – 10 Bar Vertical Pipe Mounted – 1″ – 3L Draw","offer_id":43625049980976,"sku":null,"price":99.0,"currency_code":"AUD","in_stock":true},{"title":"18L – 10 Bar Vertical Pipe Mounted – 1″ – 6L Draw","offer_id":43625050013744,"sku":null,"price":155.0,"currency_code":"AUD","in_stock":true},{"title":"35L – 10 Bar Vertical Pipe Mounted – 1″ – 11L Draw","offer_id":43625050046512,"sku":null,"price":199.0,"currency_code":"AUD","in_stock":true},{"title":"35L – 10 Bar Vertical Floor Mounted – 1″ – 11L Draw","offer_id":43625050079280,"sku":null,"price":219.0,"currency_code":"AUD","in_stock":true},{"title":"60L – 10 Bar Vertical Floor Mounted – 1″ – 18L Draw","offer_id":43625050112048,"sku":null,"price":379.0,"currency_code":"AUD","in_stock":true},{"title":"80L – 10 Bar Vertical Floor Mounted – 1″ – 29L Draw","offer_id":43625050144816,"sku":null,"price":459.0,"currency_code":"AUD","in_stock":true},{"title":"100L – 10 Bar Vertical Floor Mounted – 1″ – 36L Draw","offer_id":43625050177584,"sku":null,"price":509.0,"currency_code":"AUD","in_stock":true},{"title":"150L – 10 Bar Vertical Floor Mounted – 1″ – 54L Draw","offer_id":43625050210352,"sku":null,"price":769.0,"currency_code":"AUD","in_stock":true},{"title":"20L – 10 Bar Horizontal – 1″ – 8L Draw","offer_id":43625050243120,"sku":null,"price":155.0,"currency_code":"AUD","in_stock":true},{"title":"60L – 10 Bar Horizontal – 1″ – 22L Draw","offer_id":43625050275888,"sku":null,"price":379.0,"currency_code":"AUD","in_stock":true},{"title":"8L – 16 Bar Vertical Pipe Mounted – 1″ – 3L Draw","offer_id":43625050308656,"sku":null,"price":165.0,"currency_code":"AUD","in_stock":true},{"title":"18L – 16 Bar Vertical Pipe Mounted – 1″ – 6L Draw","offer_id":43625050341424,"sku":null,"price":199.0,"currency_code":"AUD","in_stock":true},{"title":"35L – 16 Bar Vertical Pipe Mounted – 1″ – 11L Draw","offer_id":43625050374192,"sku":null,"price":345.0,"currency_code":"AUD","in_stock":true},{"title":"80L – 16 Bar Vertical Floor Mounted – 1″ – 29L Draw","offer_id":43625050406960,"sku":null,"price":879.0,"currency_code":"AUD","in_stock":true},{"title":"24L – 25 Bar Vertical Pipe Mounted – 1″ – 8L Draw","offer_id":43625050439728,"sku":null,"price":399.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/files\/i4Hky7mE50TfMP_9dujQWexr4IjH-7jfobTi-sWnZ2IpxkZgXEQtWO_SHYeTi2lHOwBDfc1dzDQqjUHnw4agGWYao7QsDuLbo4T0Fb69cHkG4ANp3v9mZzeCNYs71tSuocIlwIHj8748_rTZZ1XU89jHGIhu509ctVPUz2YpSHhWR5Xl9ewnKWO.jpg?v=1789546252"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6494\/9808\/collections\/45c371a1-8689-44d7-8fc5-265d00920688.png?v=1789453880","url":"https:\/\/thepumpshedaustralia.com.au\/collections\/franklin-pump-accessories-controls.oembed?page=2","provider":"The Pump Shed Australia","version":"1.0","type":"link"}